Troubleshooting
10
311512A
Hose Heat
Air motor doesn’t move with air pres-
sure applied
Reversing switch failed
Inspect and repair parts; see page
32.
Solenoid valve failed
Replace valve.
Pump movement speed is erratic
Worn air motor seals
Replace seals; see page see page
32.
Worn pump seals
Replace seals; see Pump manual.
Worn solenoid valve seals
Replace solenoid valve; see pages
16 and 32.
PROBLEM
CAUSE
SOLUTION
PROBLEM
CAUSE
SOLUTION
Hose temperature controller display
flashing “SbEr” and “H20.0”
FTS not connected. Control does not
see thermocouple.
Check and connect FTS connector at
each joint; see page 20.
Hose temperature controller display
dropping with hose switch green light
on
Hose power-lock connector loose
Connect hose power-lock at Reactor
Check and reconnect all connector
points along hose. Use wire tie to
hold together.
Hose heat switch green light goes out Hose over-temperature shutdown
Measure hose for proper amperage.
Repair or replace hose power con-
trollers. See page 22. Reset
over-temperature hose control knob
to START.
Set Point 2 (SP2) deviation alarm set
too low. Raise SP2 to 30 °F (17 °C)
default setting.
Hose temperature display overshoots
setpoint and/or green switch light
goes out
Hose coiled up on itself too much,
sends overheated fluid to FTS
Straighten out coiled hose
Insulation peeled off of hose at FTS
sensor inside hose causes the rest of
hose to overheat.
Insulate hose up to FTS. FTS must
represent bulk of heated hose.
Hose heat too low
Temperature setpoint too low
Check setpoint (SP1); adjust if nec-
essary
Fluid flow too high
Use smaller mix chamber. Decrease
pressure.
Hose heat not turned on long
enough. More than 310 ft. connected.
Allow more time for hose heat to heat
up or preheat supply drums
Loose electrical connectors. Green
light on Power Controller is off.
Check power and FTS connections;
see page 20.
Either heat temperature controller
display dark
Controller connector loose
Check and reconnect
No lights on hose power controller in
lower cabinet while temperature con-
troller 01 output light is on steady.
Green switch light is on. Not heat in
hose.
No 4.5 to 12 Vdc signal from temper-
ature controller
Make sure 01 light on top tempera-
ture controller is on.
Polarity is reversed on 4.5 to 12 Vdc
Reverse blue wires.
No power to hose power controller
terminals 2 and 3; 220-240 Vac
Make sure green light on hose switch
is on. Make sure hose primary circuit
breaker is on.
Summary of Contents for Reactor A-20
Page 31: ...Parts 311512A 31 ...
Page 35: ...Parts 311512A 35 ...
Page 38: ...Reactor A 20 Wiring Schematic 38 311512A Reactor A 20 Wiring Schematic ...
Page 39: ...Reactor A 20 Wiring Schematic 311512A 39 ...
Page 40: ...Reactor A 20 Wiring Schematic 40 311512A ...
Page 41: ...Reactor A 20 Wiring Schematic 311512A 41 ...
Page 42: ...Reactor A 20 Wiring Schematic 42 311512A ...
Page 43: ...Wiring Diagrams 311512A 43 Wiring Diagrams Heater Circuit ...
Page 44: ...Wiring Diagrams 44 311512A Pump Circuit ...
Page 45: ...Wiring Diagrams 311512A 45 Hose Circuit ...
Page 46: ...Wiring Diagrams 46 311512A ...