Before performing any troubleshooting procedures:
1.
Follow
Pressure Relief Procedure, page 48
2.
Turn main power switch OFF.
3.
Allow equipment to cool.
Problem
Problem
Problem
Cause
Cause
Cause
Solution
Solution
Solution
Ambient temperature is too cold.
Relocate hoses to a warmer area
or recirculate heated fluid through
the hose.
FTS failed or not installed correctly.
Check FTS, see
.
Hose heats but heats slower
than usual or it does not reach
temperature.
Low supply voltage.
Verify line voltage. Low line
voltage significantly reduces
power available to the hose heat
system, affecting longer hose
lengths.
A and B setpoints too low.
Increase A and B setpoints.
Hose is designed to maintain
temperature, not to increase it.
Ambient temperature is too cold.
Increase A and B setpoints to
increase fluid temperature and
keep it steady.
Flow too high.
Use smaller mix chamber.
Decrease pressure.
Hose was not fully preheated.
Wait for hose to heat to correct
temperature before spraying.
Hose does not maintain
temperature while spraying.
Low supply voltage.
Verify line voltage. Low line
voltage significantly reduces
power available to the hose heat
system, affecting longer hose
lengths.
334946C