Error
Error
Error
Location
Location
Location
Type
Type
Type
Description
Description
Description
Cause
Cause
Cause
Solution
Solution
Solution
V3MB
TCM
High Voltage B
Incoming line
voltage is too high.
Ensure incoming system
power is wired properly.
Verify voltage at each circuit
breaker is between 195 and
264 VAC.
V3MH
TCM
High Voltage Hose
Incoming line
voltage is too high.
Ensure incoming system
power is wired properly.
Verify voltage at each circuit
breaker is between 195 and
264 VAC.
V4IT
TCM
High Voltage CAN
Bad 24 VDC power
supply.
Check voltage of power
supply. Voltage should
be 23-25 VDC. If out of
tolerance, replace power
supply.
V4MA
TCM
High Voltage A
Incoming line
voltage is too high.
Ensure incoming system
power is wired properly.
Verify voltage at each circuit
breaker is between 195 and
264 VAC.
V4MB
TCM
High Voltage B
Incoming line
voltage is too high.
Ensure incoming system
power is wired properly.
Verify voltage at each circuit
breaker is between 195 and
264 VAC.
V4MH
TCM
High Voltage Hose
Incoming line
voltage is too high.
Ensure incoming system
power is wired properly.
Verify voltage at each circuit
breaker is between 195 and
264 VAC.
WMI0
TCM
TCM Fan Error
Fan inside TCM
is not operating
properly.
Check for debris in the TCM
fan and clear with forced air
if necessary.
WSUX
USB
Configuration Error
USB
A valid
configuration file
can't be found for
the USB.
Inset a system token into
the ADM and cycle power.
Wait until the lights on the
USB port stop flashing
before removing token.
WXUD
ADM
USB Download Error
Log download
failed.
Backup and reformat the
USB drive. Retry download.
WXUU
ADM
USB Upload Error
Custom language
file failed to upload.
Perform normal USB
download and use the new
disptext.txt file to upload the
custom language.
36
334946C