Problem
Cause
Solution
Hoses near Reactor are warm, but
hoses downstream are cold.
Shorted connection or failed hose
heating element.
With power off, check the hose
resistance with and without the
whip hose attached. With the whip
hose attached, the reading should
be less than 3 ohm. Without the
whip hose attached, the reading
should be OL (open loop). See
Aand B temperature setpoints too
low.
Increase Aand B setpoints. Hose
designed to maintain temperature,
not increase temperature.
Hose temperature setpoint too
low.
Check. Increase if necessary to
maintain heat.
Flow too high.
Use smaller mix chamber.
Decrease pressure.
Low current; FTS not installed.
Install FTS, see operation manual.
Hose heat zone not turned on long
enough to reach setpoint.
Allow hose to heat up, or preheat
fluid.
Loose hose electrical connections. Check connections. Repair as
necessary.
Low hose heat.
Ambient temperature is to low
Relocate hoses to a warmer area
or increase Aand B setpoints.