background image

4ą307-878

SAFETY WARNINGS

HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY.

FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS

Read and understand all instruction manuals before operating equipment.

FLUID INJECTION HAZARD

General Safety
This equipment generates fluid pressure high enough to
cause an injection injury. Spray from the dispense valve
or fluid emitted under high pressure from leaks or rup-
tured components can inject fluid through your skin and
into your body and cause extremely serious bodily injury,
including the need for amputation. Also, fluid injected or
splashed into the eyes or on the skin can cause serious
damage.

NEVER point the dispensing valve at anyone or at any
part of the body. NEVER put hand or fingers over the end
of the dispensing valve.

ALWAYS follow the Pressure Relief Procedure, at right,
before cleaning or removing the nozzle or servicing any
system equipment.

NEVER try to stop or deflect leaks with your hand or
body.

Be sure equipment safety devices are operating properly
before each use.

Medical Alert––Injection Wounds
If any fluid appears to penetrate your skin, get EMER-
GENCY MEDICAL CARE AT ONCE. DO NOT TREAT
AS A SIMPLE CUT.
 Tell the doctor exactly what fluid was
injected.

Note to Physician: Injection in the skin is a traumatic in-

jury. It is important to treat the injury surgically as soon
as possible. Do not delay treatment to research toxic-
ity. Toxicity is a concern with most lubricants injected
directly into the blood stream. Consultation with a
plastic surgeon or reconstructive hand surgeon may
be advisable.

Pressure Relief Procedure
To reduce the risk of serious bodily injury, including fluid
injection or splashing in the eyes or on the skin, always
follow this procedure whenever you shut off the pump,
when checking or servicing any part of the system, when
installing or changing dispensing devices, and whenever
you stop dispensing.

1.

Close the pump air regulator.

2.

Hold a metal part of the valve firmly to a grounded
metal waste container and trigger the valve to relieve
the fluid pressure.

Dispensing Valve Safety (if applicable)
Do not modify any part of the dispensing valve. Only use
extensions and no–drip tips which are designed for use
with your dispensing valve. Modifying parts can cause a
malfunction and result in serious bodily injury, including
fluid injection and splashing in the eyes or on the skin.

Flexible Nozzle Safety
Be sure you know the maximum working pressure of the
flexible nozzle you are using. Never exceed that pres-
sure, even if your dispensing valve and/or pump is rated
for higher working pressures.

Never use a low pressure flexible nozzle, designed for
low pressure dispensing valves or hand–powered lubri-
cating equipment, on a high pressure dispensing valve.

Grease Fitting Coupler Safety
Use extreme caution when cleaning or changing grease
fitting couplers. If the coupler clogs while dispensing,
STOP DISPENSING IMMEDIATELY. Follow the Pres-
sure Relief Procedure
, above. Then remove the cou-
pler to clean it. Never wipe off buildup around the coupler
until pressure is fully relieved.

HOSE SAFETY

High pressure fluid in the hoses can be very dangerous. If
the hose develops a leak, split or rupture due to any kind
of wear, damage or misuse, the high pressure spray
emitted from it can cause a fluid injection injury or other
serious bodily injury or property damage.

TIGHTEN all fluid connections securely before each use.
High pressure fluid can dislodge a loose coupling or allow
high pressure spray to be emitted from the coupling.

NEVER use a damaged hose. Before each use, check
entire hose for cuts, leaks, abrasion, bulging cover, or

damage or movement of the hose couplings. If any of
these conditions exist, replace the hose immediately. DO
NOT try to recouple high pressure hose or mend it with
tape or any other device. A repaired hose cannot contain
the high pressure fluid.

HANDLE AND ROUTE HOSES CAREFULLY. Do not pull
on hoses to move equipment. Do not use fluids or solvents
which are not compatible with the inner tube and cover of
the hose.  DO NOT expose Graco hose to temperatures
above 180

F (82

C) or below –40

F (–40

C).

Summary of Contents for Ratio Fire-Ball 225-003

Page 1: ...ponent rupture fire or explosion which can cause serious bodily injury including fluid injection 5000 psi 350 bar Maximum Working Pressure 100 psi 7 bar Maximum Air Working Pressure Portable units for...

Page 2: ......

Page 3: ...nditions that could cause bodily injury CAUTION Alerts user to avoid or correct conditions that could cause damage to or destruction of equipment NOTE Gives additional information or helpful hints DIS...

Page 4: ...mly to a grounded metal waste container and trigger the valve to relieve the fluid pressure Dispensing Valve Safety if applicable Do not modify any part of the dispensing valve Only use extensions and...

Page 5: ...e pump follow the Pressure Relief Procedure on page 4 to prevent the pump from starting accidentally FIRE OR EXPLOSION HAZARD Static electricity is created by the flow of fluid through the pump and ho...

Page 6: ...ct the nipple 2d to the pump air inlet Connect the quick disconnect coupler 2c to the air supply hose Model 225 003 226 379 1 Assemble the base 3 as shown in the parts drawing on page 12 2 Screw the h...

Page 7: ...pass easily through the follow plate grommet 5 Secure the cover on the drum with the thumbscrews It is not necessary to bolt the pump to the cover 6 Assemble the gun 2b and hose 2a and then con nect...

Page 8: ...connect the hose to the pump fluid outlet 6 Connect the quick disconnect nipple 2d to the pump air inlet Connect the quick disconnect coupler 2c to the air supply hose 6 6b 4 3 5a 5b 5c 5d 2b 2a 2c 2d...

Page 9: ...d and shuts off when it is closed 5 Set the air pressure to each pump at the lowest pres sure needed to get the desired results WARNING The maximum working pressure of each pump in your system may not...

Page 10: ...PAlL 1 4 204 574 COVER See 306 345 for parts 1 6 203 976 HOLSTER 1 MODEL 222 069 35 to 50 lb pail size REF NO PART NO DESCRIPTION QTY 1 207 609 PUMP 50 1 Ratio President See 306 517for parts 1 2 222...

Page 11: ...s 1 2 222 070 DISPENSE KIT See parts list on page 10 1 3 203 650 TRUCK 2 wheel See parts list below 1 4 204 574 COVER See 306 345 for parts 1 5 204 134 PAIL 1 6 203 976 HOLSTER 1 REF NO 3 Truck 203 65...

Page 12: ...des items 4f 4g 1 4f 104 114 FOLLOW PLATE bare 1 4g 160 848 GROMMET 1 6 203 976 HOLSTER 1 MODEL 226 379 120 lb drum size REF NO PART NO DESCRIPTION QTY 1 203 869 PUMP 50 1 Ratio Fire ball See 306 517...

Page 13: ...5 222 061 HOLD DOWN KIT Includes items 5a 5d 1 5a 200 889 NUT wing 2 5b 153 166 HOOK drum mounting 2 5c 153 102 ROD drum 2 5d 159 016 BRACKET retaining 2 used 4 6 222 243 CART KIT Includes items 6a 6n...

Page 14: ...yond the pre adjusted setting due to an empty supply container interrupted fluid supply to the pump or excessive cavitation 3 4 npt f Grounding Clamp Wire 222 011 12 ga 25 ft 7 6 m wire Air Line Filte...

Page 15: ...F NO PART NO NAME 222 070 OLD 101 150 163 Fluid Hose Dispense Kit NEW 101 109 150 Fluid Hose INTERCHANGEABILITY NOTE NEW parts replace OLD parts listed directly above them ADDED PRODUCT NOTE Model 222...

Page 16: ...pairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation DISCLAIMERS AND LIMITATIONS THE TERMS OF THIS WARRANTY CONSTITUTE PURCHASER S SOLE AND E...

Reviews: