![Graco ProMix Auto Series Service Parts Download Page 26](http://html1.mh-extra.com/html/graco/promix-auto-series/promix-auto-series_service-parts_2253522026.webp)
Service
26
311189L
Servicing Fluid Manifold
Removing
1.
procedure, steps
1-7, page 25.
2.
Disconnect air and fluid lines from the manifold (5).
3.
Remove 4 screws (34). To ease screw removal, use
a long T-handle Allen wrench.
4.
Remove A and B meter bracket screws.
5.
Remove the 3 screws behind the fluid manifold.
6.
Remove fluid manifold (5).
7.
Service fluid manifold as instructed in the Fluid Mix
Manifold manual.
Installing
1.
Install the 3 screws behind the fluid manifold.
2.
Secure fluid manifold (5) and mounting plate (35)
with 4 screws (34).
3.
Install A and B meter (1) bracket screws. See steps
9-11,Installing, Page 24.
4.
Connect air and fluid lines.
NOTE: There are two different size integrators:
50cc and 25cc. 25cc is etched on the outside of
the 25cc integrator component.
F
IG
. 30
34
35
TI4859a
5