6
308783
Icons
Operation Mode Icons
The system is in Operation Mode when it is powered
up. The operations that are commonly used in every-
day operation appear as icons on the keypad. These
icons include:
TARGET RATIO:
Press to display the
ratio that the ProMix Proportioner has
been setup to produce.
ACTUAL RATIO:
Press to display the
actual ratio the ProMix is producing.
TOLERANCE:
Press to display the ratio
tolerance that the ProMix Proportioner is
currently producing.
COMPONENT A:
Press to display the
amount of component A that has been
dispensed since the last time the report
button on the operator station was
pressed. Amount will be in gallons or
liters, depending on how system was
setup.
COMPONENT B:
Press to display the
amount of component B that has been
dispensed since the last time the report
button on the operator station was
pressed. Amount will be in gallons or
liters, depending on how system was
setup.
POT LIFE TIME:
Press to display the pot
life time remaining in minutes.
Note:
Pot life is the approximate length of
time mixed fluid can remain in the system
and stay at its normal viscosity. The time
length is entered during setup.
FLOW RATE:
Press to display the cur-
rent flow rate the system is producing in
cc per minute.
Setup Mode Icons
Read page 15 for information on the
Reference Card
and how to use it to select setup functions, which are
represented by the following icons.
When a key for a function is pressed, the light below
that function will turn green and the last known value
for that function will display.
Adjust the displayed values using the up and down
arrow keys (
no
) .
RETURN:
The system enters setup at
level 1. Press the return arrow to direct
the control to the next level of setup,
which is level 2; then level 3; then back to
level 1.
Level 1 Icons
SOLVENT VALVE:
Hold down the key to
open the solvent valve to clean the ratio
check valves after a ratio check. The
valve closes when the key is released.
TARGET RATIO:
Press to adjust the
desired ratio. Can be set from 0.6:1 to
20.0:1.
LITER/GALLON:
Press to set value to
liters or gallons for totalizer display val-
ues.