Service
WARNING
INJECTION HAZARD
To reduce the risk of a serious injury,
follow the
Pressure Relief Procedure
on page 17 before checking or servicing
the equipment.
WARNING
ELECTRIC SHOCK HAZARD
To reduce the risk of electric shock, the
air to the air driven power supply must
be shut off before servicing the control. If
an external power supply is used, make
sure its power is turned off.
CAUTION
Wear the grounding strap provided when servicing
the control to avoid shorting out the circuit board.
CAUTION
Do not use any fluid in the line that was dispensed
off ratio as it may not cure properly.
NOTE:
If the ratio is set to 0.6:1 to 20:1, the ratio will
remain at its setting when powered off and on. If the
ratio is set to 0.5:1 or less and the system is powered
off and on, the ratio will reset to the default of 1:1. All
other settings will also reset to their default values.
Instruction Manuals
Additional instruction manuals are included with the
ProMix control. To maintain, service, or order parts for
an individual component, such as the meter, refer to its
instruction manual.
Description
Part No.
Instruction
Manual No.
G3000 Meter
239716
308778
Mix Manifold
239732
308288
Hardware or Software Updates
Check with your Graco representative periodically to
see if hardware or software updates are available.