Replace
Replace
Replace the
the
the Pressure
Pressure
Pressure Switch
Switch
Switch
Note
This part is not used on Electronic Air
Controllers.
Follow these directions to replace the pressure switch
(101, Kit 26A292).
1.
Follow directions at
.
2.
Disconnect the air tubing (26).
3.
Disconnect the wires (110) from the pressure
switch (101).
4.
Remove two screws (96), then remove the
pressure switch assembly.
5.
Use screws (96) to attach the pressure switch
assembly to the box.
6.
Reconnect the wires (110).
Pressure
Pressure
Pressure Switch
Switch
Switch Wire
Wire
Wire
Terminal
Terminal
Terminal Block
Block
Block
COM
11
NO
12
NC
13
7.
Reconnect the air tubing (26).
Replace
Replace
Replace a
a
a Pressure
Pressure
Pressure Gauge
Gauge
Gauge
Note
This part is not used on Electronic Air
Controllers.
Follow these directions to replace the pressure gauge
(104)
1.
Follow directions at
.
2.
Remove the air tubing (26).
3.
Loosen the swivel on elbow (107).
4.
Remove the nuts (104a and 40b) the bracket
(104c) and the pressure gauge (104).
5.
Install a new pressure gauge (104). Slide the
bracket (104c) onto the gauge and secure with
nuts (104a and 104b).
6.
Tighten the swivel on the elbow (107).
7.
Reconnect the air tubing (26).
30
3A3954D