Installation
12
309572M
Connect 261669 FTS and Heated Dual Whip Hose
1. Carefully extend FTS probe (H) into the
hose section from the proportioner. Do not
bend or kink probe. Insert in component A
(ISO) side of main hose for foam or poly-
urea systems.
2. Connect FTS (J) to whip hose (W).
3. Connect whip hose ground wire (K) to
ground screw on underside of FTS.
4. Connect fluid hoses to FTS (J).
5. Connect electrical connectors (D).
6. Connect air hose (C) to whip air hose (L).
7. Connect hose assembly cable (F) to FTS
cable (R). Slide insulator sleeves (S) over
connection. Leave slack (G) in cables as
stress relief, to prevent cable failure.
8. See Check Hoses for Leaks, page 14
CAUTION
To prevent damage to probe, do not kink or
excessively bend hose. Do not coil hose
tighter than the minimum bend radius of 3 ft
(0.9 m). Do not subject hose to excessive
weight, impact, or other abuse.
To use 1/2 in. (13 mm) ID fluid hoses,
remove the adapters from the propor-
tioner fluid manifold and install them in
the FTS swivel inlets.
B
A
A
B
K
H
C
D
J
L
TI9581B
F
G
W
S
S
R
To Gun
To Proportioner