Grounding
313877J
9
PD44 Dispense Valve
See the PD44 Dispense Valve Operation-Parts manual
for detailed dispense valve component identification and
on page 2.
Grounding
Control box:
this product is equipped with a cord
having a grounding wire with an appropriate grounding
plug. The plug must be plugged into an outlet that is
properly installed and grounded in accordance with all
local codes and ordinances.
Air and fluid hoses:
use only electrically conductive
hoses.
Fluid supply container:
follow local code.
Solvent pails used when flushing:
follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive
surface, such as paper or cardboard, which interrupts
grounding continuity.
F
IG
. 2: PD44 Micrometer Dispense Valve
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.