HMI Operation
313877J
15
Timer/Counter Control Screen
NOTE:
A”1” indicates the mode is ON. A “0” indicates
the mode is OFF.
Calculating the Purge Timer Setting
If the shot size is larger than the mixer volume, set the
timer for one-half the gel time of the material. If the shot
size is smaller, use the following formula to determine
the Purge Timer setting.
For example, with mixer volume = 13.3cc, shot size =
10cc, gel time = 10 minutes, use the following equation.
F
IG
. 9: Timer/Counter Control Screen
Gel Time X Shot Size
= Timer Setting
2 X Mixer Volume
10 min X 10 cc
=
100 cc*min
= 3.76 min
2 X 13.3 cc
26.6 cc