Operation
312798J
23
Adjust the Spray Pattern
1.
See F
IG
. 7. Close off pattern adjustment air by turn-
ing knob clockwise (in) all the way. This sets gun for
its widest pattern.
2.
See F
IG
. 8. Set atomizing air pressure at about 5 psi
(0.35 bar, 35 kPa) when triggered. Check spray pat-
tern, then slowly increase air pressure until tails are
completely atomized and pulled into spray pattern.
Do not exceed 100 psi (0.7 MPa, 7 bar) air pressure
to gun.
3.
For narrower pattern, turn pattern adjustment valve
knob counterclockwise (out). If pattern is still not
narrow enough, increase air pressure to gun slightly
or use different size tip.
NOTE: Follow directions in your gun operation manual
(supplied) to test the electrostatics and to check cover-
age and wrap on a test piece. See Troubleshooting in
your gun operation manual if there is a problem.
Shutdown
Follow Pressure Relief Procedure, page 20.
Always flush the pump before the fluid dries on the dis-
placement rod. See Flush the Pump on page 24.
F