![background image](http://html1.mh-extra.com/html/graco/magnum-289680/magnum-289680_instructions_2251313002.webp)
2
312930A
Enclosure Replacement Kit 289680, 289681
Disassembly
1.
Unplug electrical cord and
Relieve Pressure
(see
page 1 or Operation manual 312001).
2.
Remove 4 side shroud screws (E) (T-20 Torx).
3.
Remove 4 front cover screws (B) (T-30 Torx).
4.
X7 and LTS 17 Only:
Remove underside shroud
screw (D).
5.
Remove right shroud (G).
6.
Remove left shroud (K).
7.
Remove ON/OFF (L) switch from left shroud (K).
Assembly
1.
Install ON/OFF switch (L) into left shroud (K).
2.
Install power cord (N) into recess on left shroud (K).
3.
Reassemble both shrouds (G and K).
4.
Install 4 side shroud screws (E) (T-20 Torx). Torque
to 20 to 25 in-lb (2.3 to 2.8 N•m).
5.
Install 4 front cover screws (B) (T-30 Torx). Torque to
26 to 32 in-lb (2.9 to 3.6 N•m).
6.
X7 and LTS 17 Only:
Install underside shroud
mounting screw (D). Torque to 25 to 35 in-lb (2.8 to
3.9 N•m).
ti10231a
E
K
D
B
G
N
L
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
www.graco.com