HMI Operation
22
313877G
Level 1 Control Screen
NOTE:
The Error Code button is shown on every screen
on the Motor Driven PD44. See the Main screen for defi-
nition, page 16.
NOTE:
If ‘A Tank Status’ and ‘B Tank Status’ both dis-
play 'Levels Not Active' then the level control feature is
not installed on this machine.
A Tank Status, B Tank Status
This displays information about each component tank
filling process. The following are the possible messages.
Silence Alarm button
This button silences the audible alarm when pressed.
Start Fill A, Start Fill B button
When this button is pressed the transfer pump fills the
tank until the material level reaches the high level sen-
sor on that tank.
NOTE:
The Start Fill A, Start Fill B and the Stop Fill but-
tons are inoperable if the high level automatic tank refill-
ing feature was not purchased with this machine.
Stop Fill button
This button stops the automatic tank refilling process for
both the A and B component material tanks.
Micrometer PD44 and LRT PD44 Level 2 Control screen shown
Message
Description
Material
High
The tank level is at or above the high level sen-
sor.
Material
Low
The tank level is below the low level sensor.
Filling
The tank is currently refilling in the tank refilling
process.
Material
Present
The tank level is between the high and the low
level sensors.
Level Sen-
sor Fault
The machine senses material at the high level
sensor but not at the low level sensor.
Levels Not
Active
Level sensors are not installed for the tank.
Fill Fault
The tank began refilling and the fluid level did not
reach the high level sensor within the preset time
entered into the Fill Timer button seen in the Lev-
el2 Control screen. Tank has stopped refilling.