Startup
12
313877G
Startup
NOTE:
See
starting on page 14 for
detailed HMI instructions.
1. Press the Control Power On button.
2.
On Micrometer and LRT PD44s,
navigate to the
Posidot
®
Control screen.
On Motor Driven PD44s,
navigate to the Metering
Valve Control screen.
3. Under Posidot Mode, press the Retract button.
NOTE: On LRT and Motor Driven PD44s,
when there
is an Emergency Stop condition or the system power is
lost, the shot selection resets to “0”. The operator must
then select a shot.
NOTE: On Micrometer PD44s,
skip steps 4-7.
4. Navigate to the Shot Size screen.
5. Select a shot number.
6. Navigate to the Pump Mode screen.
NOTE:
Upon power up, “Error Code 130 Position Mod-
ule is not Enabled” will be shown. Press the Retract
(Home) button to allow the dispense valve metering rod
connecting block to move to the reload position.
7. Press the Shot button to select Shot Mode.
8. Verify air pressure is set to 80 psi (5.6 bar).
9. Perform feed system startup procedure(s). See
on page 3.
10. Perform dispense valve startup procedure. See
on page 3.