Pressure Control
18
312195B
Control Board
Removal
1.
Relieve pressure, page 6.
2.
. 13. Remove two screws (125) and control cover
(31). Pull display connector wings open on control
board and pull display connector out.
3.
. 21. Note on a paper lead connec-
tions to the control board. Disconnect leads from
control board (15d).
4.
. 13. Remove five screws (15j) from control
board (15d).
Installation
1.
. 13. Install control board (15d) with five screws
(15j).
2.
. 21. Refer to note on lead connec-
tions to the control board. Connect leads to control
board (15d).
3.
. 13. Push display connector into control board
close display connector wings on control board.
Install control cover (31) with two screws (125).
Pressure Control Transducer
Removal
1.
Relieve pressure, page 6.
2.
. 13. Remove two screws (125) and control cover
(31).
3.
Disconnect transducer lead (C) from control board
(15d).
4.
Remove pressure control transducer (216) and
o-ring (217) from filter manifold (40).
Installation
1.
. 13. Install o-ring (217) and pressure control
transducer (216) in filter manifold (40). Torque to
35-45 ft-lb.
2.
Connect transducer lead (C) to control board (15d).
3.
Install control cover (31) with two screws (125).
Pressure Adjust Potentiometer
Removal
1.
Relieve pressure, page 6.
2.
. 13. Remove two screws (125) and control cover
(31).
3.
Disconnect lead (D) from control board (15d).
4.
Loosen set screws on potentiometer knob (15o) and
remove knob, shaft nut, lockwasher and pressure
adjust potentiometer (15i).
5.
Remove seal (15n) from potentiometer (15i).
Installation
1.
Install seal (15n) on potentiometer (15i).
2.
. 13. Install pressure adjust potentiometer (15i),
shaft nut, lockwasher and potentiometer knob (15o).
a.
Turn potentiometer shaft (15i) clockwise to inter-
nal stop. Assemble potentiometer knob (15o) to
strike pin on plate (15r).
b.
After adjustment of step a, tighten both set
screws in knob 1/4 to 3/8 turn after contact with
shaft.
3.
Connect lead (D) to control board (15d).
4.
Install control cover (31) with two screws (125).