Troubleshooting (ES 1000 & ES 2000)
3A4603F Operation, Repair, Parts
63
Sprayer does not run at all
Check transducer or transducer
connections (control board is not
detecting a pressure signal).
1.
Set sprayer to OFF and disconnect power to
sprayer.
2.
Check transducer and connections to control board.
3.
Disconnect transducer from control board socket.
Check to see if transducer and control board
contacts are clean and secure.
4.
Reconnect transducer to control board socket.
Connect power, set sprayer ON and control knob
to 1/2 turn clockwise. If sprayer does not run,
set sprayer to OFF and go to next step.
5.
Connect a confirmed working transducer to control
board socket.
6.
Set sprayer ON and control knob to 1/2 turn
clockwise. If sprayer runs, install new transducer.
Replace control board if sprayer does not run.
7.
Check transducer resistance with ohmmeter (less
than 9k ohm between red and black wires and 3-6k
ohm between green and yellow wires).
Control board status light blinks
3 times repeatedly
Sprayer does not run at all
Check voltage supply to the sprayer
(control board is detecting multiple
voltage surges).
1.
Set sprayer to OFF and disconnect power to
sprayer.
2.
Locate a good voltage supply to prevent damage to
electronics.
3.
See
Control board status light blinks
4 times repeatedly
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK
Summary of Contents for LineLazer ES 1000
Page 38: ...ES2000 HP Auto Series 38 3A4603F Operation Repair Parts ES2000 HP Auto Series ...
Page 91: ...Wiring Diagram 230V ES 1000 3A4603F Operation Repair Parts 91 Wiring Diagram 230V ES 1000 ...
Page 109: ...Wiring Diagram 120V ES 2000 3A4603F Operation Repair Parts 109 Wiring Diagram 120V ES 2000 ...
Page 112: ...Wiring Diagram 230V ES 2000 112 3A4603F Operation Repair Parts Wiring Diagram 230V ES 2000 ...