7.
Spray a test pattern. Read fluid manufacturer’s
recommendations. Adjust as necessary.
NOTE:
NOTE:
NOTE: When determining the desired spray
pressure, always increase the spray pressure
until the spray pattern fully develops. This will
reduce the pressure surge when the pump is
stalled and minimize over-spray.
Dynamic
Dynamic
Dynamic Pump
Pump
Pump Outlet
Outlet
Outlet Pressure*
Pressure*
Pressure*
E60
E60
E60
E50
E50
E50
Pressure
Pressure
Pressure
Adjustment
Adjustment
Adjustment
Knob
Knob
Knob Setting
Setting
Setting
PSI
PSI
PSI
Bar
Bar
Bar
MPa
MPa
MPa
PSI
PSI
PSI
Bar
Bar
Bar
MPA
MPA
MPA
1
500
35.0
3.5
400
27
2.7
2
1000
70.0
7.0
800
54
5.4
3
1500
105
10.5
1200
81
8.1
4
2000
140
14.0
1600
108
10.8
5
2500
170
17.0
2000
135
13.5
6
3000
205
20.5
2400
162
16.2
7
3500
240
24.0
2800
189
18.9
8
4000
275
27.5
3200
216
21.6
9
4500
310
31.0
3600
243
24.3
10
5000*
344*
34.4*
4000*
270*
27.0*
*The sprayer can stall at pressures higher than the
dynamic pressure. All components downstream
of the sprayer must be rated for the pressures
listed in
8.
Flush when finished spraying.
Perform
and
...
18
3A8126B