Installation
334627K
9
Recommended Air Setup
1.
Connect tubing from the air filter (Graco part no.
106148) to the air regulator.
2.
Set the air regulator to 80 psi (0.5 MPa, 5.5 bar).
3.
Connect the tubing from the air regulator to the
applicator solenoid.
Connect Solenoid Valve
1.
Connect 1/2 in. diameter air supply tubing to a a
clean, dry, and non-lubricated air supply and to the
push-to-connect air inlet fitting (L).
2.
Connect the solenoid (J) to the 24 VDC signal. See
Connect Triggering Device
on this page.
NOTE:
A 6 mm tube fitting is included with the
applicator. The fitting can be changed using a 5 mm
Allen wrench. A 1/4 in . to 3/8 in. diameter tube adapter
is included with the applicator.
Connect Triggering Device
All GM100 valves use a 24 VDC solenoid valve. If the
voltage to the solenoid exceeds 24 VDC, premature
failure will occur.
Before Using Equipment
The equipment was tested with canola oil, which is left
in the fluid passages to protect parts. To avoid
contaminating your fluid with oil, prime the equipment
with hot melt until all of the oil is pushed out before using
the equipment. See
Flush
F
IG
. 5
F
IG
. 6
WLD
WLD
/
-
Improper electrical connection can result in electric
shock. All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
F
IG
. 7
Standard Wiring Colors
Terminal Cable
Function
M8
Plus (+)
24 V Supply
Brown
Minus (-)
Return
Blue/Black
WLD