Troubleshooting
14
334627K
Applicator will not heat
Heater failure
Check and replace the heater
cartridge. See
Replace Heater
Cartridge
on page
Loose cordset connection
Check connection.
RTD failure
Check and replace the RTD. See
Check RTD
.
Incorrect RTD for adhesive delivery
system
Check the delivery system RTD
requirement.
Thermal cutoff failure
Check and replace the thermal
cutoff. See
Replace Thermal
Cutoff
on page
.
Wrong RTD type selected
Check the RTD type settings on the
system. Change if necessary. See
Select RTD
on page
.
Applicator overheats
Heater failure
Check and replace the heater
cartridge. See
Replace Heater
Cartridge
on page
RTD failure
Check and replace the RTD. See
Check RTD
.
Incorrect RTD for adhesive delivery
system
Check the delivery system RTD
requirement.
Incorrect power to heater
Check and correct power.
Wrong RTD type selected
Check the RTD type settings on the
system. Change if necessary. See
Select RTD
on page
.
Applicator under-heats
Heater failure
Check and replace the heater
cartridge. See
Replace Heater
Cartridge
on page
RTD failure
Check and replace the RTD. See
Check RTD
.
Incorrect RTD for adhesive delivery
system
Check the delivery system RTD
requirement.
Incorrect power to heater
Check and correct power.
Wrong RTD type selected
Check the RTD type settings on the
system. Change if necessary. See
Select RTD
on page
.
Adhesive leaking from applicator
Module o-ring failure
Check and replace the o-ring. See
Replace Module
on page
.
Inlet fitting loose
Tighten the fitting.
Manifold filter o-ring failure
Check and replace the o-ring.
Nozzle loose
Tighten the nozzle.
Problem
Cause
Solution
Summary of Contents for InvisiPac GM100 Plug-Free