Speed has reduced on one module
Low air pressure to solenoid valve
Check the air supply.
Low fluid pressure
Check the adhesive delivery system.
Low applicator temperature
Check the heat operation. See the
“Applicator will not heat” section on
page
14
.
Plugged manifold filter
Replace the manifold filter. See
Replace Inlet Filter
on page
Module piston seal air leak
Check the solenoid air close exhaust
port. See
Replace Module
on page
Adhesive out of all modules when
not triggered
Solenoid valve failure
Check and replace the solenoid
valve.
Adhesive pressure too high
Check and reduce the fluid
pressure.
Solenoid valve connected incorrectly
Check the solenoid valve air
connections.
Module failure
Check and replace all module. See
Check Module
on page
.
No air to solenoid valve
Check the air supply.
Problem
Cause
Solution