System
System
System Screen
Screen
Screen
Pump
Pump
Pump Ratio:
Ratio:
Ratio: The relationship between the air
pressure supplied and the resulting fluid pressure.
Choose 30:1 or 15:1 depending on the size of the
Merkur AA fluid pump in the system.
Gun
Gun
Gun Flush
Flush
Flush Box:
Box:
Box: Enable if using a gun flush box.
Fill
Fill
Fill Start
Start
Start Delay:
Delay:
Delay: The number of seconds that the
system waits after the gun trigger is released before
it lowers the isolation valve (G) and the system
discharges.
During the course of a spraying operation, the
operator may need to briefly release the gun trigger
before painting another part. Increase the time if you
want the charge to last longer after the gun trigger is
released. (Default: 3 seconds.)
The length of time between when the gun trigger is
released and system discharge is a combination of
two settings: the Ground Rod Delay time and the Fill
Start Delay time.
For example, if the Fill Start Delay is set to 7 and the
Ground Rod Delay is set to 5:
1.
The gun trigger is released.
2.
After 5 seconds the ground rod lowers.
3.
In 2 more seconds the isolation valve lowers.
The actual time that the system takes to discharge
depends on these settings, the gun type, and the
hose length.
Ground
Ground
Ground Rod
Rod
Rod Delay:
Delay:
Delay: The number of seconds that the
system waits after the gun trigger is released before
it lowers the ground rod (N), instantly dissipating the
charge.
Color
Color
Color Change:
Change:
Change: Select this box to enable color change
capability.
Colors:
Colors:
Colors: Select the number of colors that will be used.
A system with six color change valves allows 3
colors. A system with 18 color change valves allows
15 colors.
Dump
Dump
Dump Enable:
Enable:
Enable: Select this box if the dump valve
is connected to a hose that empties into a waste
container. If the dump valve is not connected to a
hose, the remaining contents from the isolation fluid
pump will spill out of the system.
Restart
Restart
Restart System:
System:
System: Select this box to restart the entire
system. This is primarily used for initiating a token
software update without manually cycling the power.