Technical
Technical
Technical Data
Data
Data
ChemSafe
ChemSafe
ChemSafe 1040
1040
1040 Diaphragm
Diaphragm
Diaphragm Pump
Pump
Pump
US
US
US
Metric
Metric
Metric
Maximum fluid working pressure
100 psi
0.69 MPa, 6.9 bar
Minimum air startup pressure
30 psi
0.21 MPa, 2.1 bar
Fluid inlet and outlet size
1 in. npt
1 in. bspt
Maximum suction lift (reduced if balls don’t
seat well due to damaged balls or seats,
lightweight balls, or extreme speed of cycling)
Wet:
31.2 ft
Dry: 13.1 ft
Wet:
9.5 m
Dry: 4 m
Maximum size pumpable solids
0.24 in.
6 mm
Minimum recommended ambient air
temperature for operation and storage.
NOTE:
NOTE:
NOTE: ChemSafe pumps may be operated
in low temperature environments. Take care
to avoid freezing or crystallization of the
fluid inside or outside of the pump. Running
the pump at temperatures below freezing
may accelerate the wear of the elastomer
components in the pump.
32° F
0° C
Air consumption at maximum flow
46 scfm
1.3 scmm
Fluid flow per cycle
0.148 gallons
0.560 liters
Maximum free-flow delivery
39 gpm
146 lpm
Maximum pump speed
260 cycles per minute
Weight; PTFE [UHMW]
40 lb [26 lb]
18 kg [12 kg]
Wetted Parts
PTFE, EPDM, NBR, UHMWPE
Maximum
Maximum
Maximum fluid
fluid
fluid temperature
temperature
temperature
PTFE Pumps
212° F
100° C
UHMWPE Pumps
158° F
70° C
Noise
Noise
Noise (dBa)
(dBa)
(dBa)
Sound power measured per ISO-9614-2: 1997. Sound pressure was tested 3.28 ft (1 m) from equipment.
Sound Power
At 100 cycles per minute
61.6 dBa
At 260 cycles per minute
78.3 dBa
Sound Pressure
At 100 cycles per minute
70.9 dBa
At 260 cycles per minute
83.8 dBa
334795B
31
Springer Pumps, LLC
Telford, PA 18969
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
shop.springerpumps.com