Troubleshooting
8
309834W
Troubleshooting
The sensor is not a serviceable part. Replace it if
it is malfunctioning.
Problem
Cause
Solution
No flow volume displayed at monitor-
ing unit
Flow volume is too low to measure
Increase flow volume.
Fluid is not flowing
See
Problem:
Fluid is not flowing,
below.
Damaged cable
Replace cable.
Improper input voltage to sensor
Make sure input power is 10-30 Vdc.
Damaged sensor
Replace sensor if it is malfunctioning.
Fluid is not flowing
Clogs in fluid line or in meter
Clean fluid line and/or meter; see
Maintenance
section.
Gears worn or damaged
Service meter; see
Maintenance
section.