Spray Tip Selection Chart
333011D
45
Spray Tip Selection Chart
AEM Fine Finish Spray Tips
Recommended for high finish quality applications at low and medium pressures. Order desired tip, Part No. AEMxxx,
where xxx = 3-digit number from the matrix below.
Orifice
Size in.
(mm)
Fluid Output
fl oz/min (l/min)
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
at 600 psi
(4.1 MPa,
41 bar)
at 1000 psi
(7.0 MPa,
70 bar)
2 - 4
(50 -
100)
4 - 6
(100 -
150)
6 - 8
(150 -
200)
8 - 10
(200 -
250)
10 - 12
(250 -
300)
12 - 14
(300 -
350)
14 - 16
(350 -
400)
16 - 18
(400 -
450)
Spray Tip
0.007
(0.178)
4.0
(0.1)
5.2
(0.15)
107
207
307
0.009
(0.229)
7.0
(0.2)
9.1
(0.27)
209
309
409
509
609
0.011
(0.279)
10.0
(0.3)
13.0
(0.4)
211
311
411
511
611
711
0.013
(0.330)
13.0
(0.4)
16.9
(0.5)
213
313
413
513
613
713
813
0.015
(0.381)
17.0
(0.5)
22.0
(0.7)
215
315
415
515
615
715
815
0.017
(0.432)
22.0
(0.7)
28.5
(0.85)
217
317
417
517
617
717
0.019
(0.483)
28.0
(0.8)
36.3
(1.09)
319
419
519
619
719
0.021
(0.533)
35.0
(1.0)
45.4
(1.36)
421
521
621
721
821
0.023
(0.584)
40.0
(1.2)
51.9
(1.56)
423
523
623
723
823
0.025
(0.635)
50.0
(1.5)
64.8
(1.94)
425
525
625
725
825
0.029
(0.736)
68.0
(1.9)
88.2
(2.65)
829
0.031
(0.787)
78.0
(2.2)
101.1
(3.03)
431
631
831
0.033
(0.838)
88.0
(2.5)
114.1
(3.42)
833
0.037
(0.939)
108.0
(3.1)
140.0
(4.20)
737
0.039
(0.990)
118.0
(3.4)
153.0
(4.59)
539
* Tips are tested in water.
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
where QT = fluid
output (fl oz/min) at 600 psi from the above table for the selected orifice size.