Installation
12
333011D
Manifold Connections
F
IG
. 5 Manifold Connections
A2
A1
CYL
P
TA
1
2
EXH
Bottom Inlet
Rear Inlet
P
CYL
EXH
TA
2
1
A1
A2
A1
Atomization Air Inlet Fitting
Connect a 5/16 in. (8mm) OD tube between this fitting and the air supply.
A2
Fan Air Inlet Fitting
Connect a 5/16 in. (8 mm) OD tube between this fitting and the air supply.
CYL
Cylinder Air Inlet Fitting
Connect a 5/32 in. (4 mm) OD tube between this fitting and the solenoid. For quicker response, use the
shortest hose length possible.
1
Fiber Optic Fitting Transmit (Operational on Smart models only)
Connect the Graco Fiber Optic cable (see page 13).
2
Fiber Optic Fitting Receive (Operational on Smart models only)
Connect the Graco Fiber Optic cable (see page 13).
P
Fluid Supply Inlet Fitting
Connect a 1/4 npsm swivel fitting between this fitting and the fluid supply.
TA
Turbine Air Inlet Fitting
Connect the Graco Grounded Turbine Air Hose between this fitting (left-hand thread) and the solenoid.
Connect the air hose ground wire to a true earth ground.
EXH
Exhaust
Connect an exhaust tube to route the turbine
exhaust air. Fitting is for a 5/16 in OD tube.