Troubleshooting
333011D
27
Electrical Troubleshooting
Problem
Cause
Solution
Poor wrap.
Turbine air is not turned on.
Turn on.
Booth exhaust velocity is too high.
Reduce velocity to within code limits.
Atomization air pressure too high.
Decrease.
Fluid pressure too high.
Decrease, or replace worn tip.
Incorrect distance from gun to part.
Should be 8-12 in. (200-300 mm).
Poorly grounded parts.
Resistance must be 1 megohm or
less. Clean workpiece hangers.
Faulty gun resistance.
See
Test Gun Resistance
on page
22.
Low fluid resistivity.
Check Fluid Resistivity
, page 15.
Fluid leaks from the fluid needle
packings and causes a short
Clean the fluid needle cavity and see
Fluid Needle Replacement, page 31
Faulty turbine
See
Turbine Removal and
Replacement
page 34
No power.
Replace power supply, see page 33
ES indicator light is not lit (standard
models only)
No power
Check power supply, turbine, turbine
ribbon cable. See
Power Supply
Removal and Replacement
, page
33 and
Turbine Removal and
Replacement
, page 34.
ES indicator light is amber (standard
models only)
Turbine speed is too low
Increase air pressure until indicator is
green.
ES indicator light is red (standard
models only)
Turbine speed is too high
Decrease air pressure until indicator
is green
No voltage or low voltage reading on
the Pro Xp Auto Control module
Damaged fiber optic cable or con-
nection.
Check; replace damaged parts. See
Pro Xp Auto Control Module manual
332989.
Turbine air is not turned on.
Turn on.
Pro Xp Auto Control Module displays
event code (smart models only)
See manual 332989 for Event Code
Troubleshooting.