Installation
Models 222245 and 240882 (Fig. 5)
1.
Assemble the cart (6) as shown at right. Use only
2 of the 4 brackets (5d) supplied. Install the rear
positions of the drum shelf (6b) as shown.
2.
Place an open 120-lb drum of grease on the drum
shelf.
3.
Press the follow plate (4) down firmly onto the
grease, and rotate it to eliminate any air pockets
and reduce channeling. Insert the pump through
the cover (3). Slide the cover up far enough to
allow the pump to pass easily through the follow
plate grommet and into the grease.
4.
Using items 3a to 5d, secure the cover to the
drum, and the drum to the cart. It is not necessary
to bolt the pump to the cover.
5.
Assemble the gun (2b) and hose (3a), and connect
the hose to the pump fluid outlet.
6.
Connect the quick-disconnect nipple (2d) to the
pump air inlet or air regulator (7b) inlet, whichever
is applicable. Connect the quick-disconnect
coupler (2c) to the air supply hose.
Fig. 5
2b
2c
2d
3
6
4
6b
5a
5b
5c
5d
Model 240882 shown
01518A
2a
7b
Summary of Contents for FIRE-BALL