Installation

WARNING

To reduce the risk of serious injury, including elec-
tric shock or splashing fluid in the eyes or on the
skin, always follow this procedure before servicing
any part of the metering system and before check-
ing for loose or shorted wires.

1.

Turn off the control, and unplug it.

2.

Shut off the power to the pump(s).

3.

Relieve the fluid pressure.

CAUTION

To avoid damaging the electronic components of the
pulse meter module (1)

D

Do not lay anything on the module.

D

Be sure the open side of the pulse module faces
up if you lay it down.

D

Do not twist or force parts.  Align parts properly
as instructed.

NOTE:

 All pulse meters are bi-directional.

To Install or Remove the Complete Pulse Meter

1.

Observe the Warning and Caution above.

2.

Disconnect the cable from the pulse module,
taking note of the wiring polarity.

3.

Remove the old pulse meter and install the new
one, observing the original wiring polarity.

To Replace the Electronic Pulse Module

4.

Observe the Warning and Caution at left.

5.

If you are replacing the pulse module, disconnect
the cable, taking note of the wiring polarity.

6.

Remove the screws, and lift off the pulse module.

7.

Install a new pulse module (1). Align the notch on
the side of the pulse module with the notch on the
side of the metering unit. Use the new screws and
torque them oppositely and evenly to 3 to 5 in-lb
(0.34 to 0.57 N.m). See Fig. NO TAG.

8.

Connect the pulse module wires to the cable,
observing the original wiring polarity.

Fig. 1

1

2

Replacement screws

included

Torque oppositely and

evenly to 3 to 5 in-lb

(0.34 to 0.57 N.m)

040
89

To Verify the Accuracy of a Pulse Meter
Module

1.

Use a clean, calibrated container. If using a single
container, be sure to clean it after each dispense.

2.

Have pump air pressure at the lowest possible
setting for dispensing fluid.

3.

Put the tip of the nozzle at the bottom of the
calibrated container.

4.

If the tip of the dispense valve does not reach the
bottom of the calibrated container, use a length of
plastic tubing over the tip of the nozzle to ensure
liquid enters the container from the bottom.

5.

Trigger the gun slowly so the fluid immediately
covers the tip of the dispense valve.

6.

Dispense 1 quart of fluid according to the metered
display on the dispense valve.

7.

Allow product to sit for 20 minutes, then compare
the actual, physical measurement in the calibrated
container to the measurement displayed on the
meter.

NOTE: 

The procedure above will determine if the

meter is accurately dispensing the product and mini-
mize testing errors. Some variance may occur depend-
ing on the viscosity of the fluid. If this procedure deter-
mines that the meter is not accurate, recalibrate the
meter as described in the service manual or replace
the meter or the electronics as necessary.

Summary of Contents for EFC C Series

Page 1: ...ectronic Fluid Commander Model No 223655 Series C Replacement Pulse Module Model No 236763 Series A Pulse Module and Meter pints quarts gallons Model No 236764 Series A Pulse Module and Meter liters Horizont Model No 239367 Series A Replacement Pulse Module Model No 238618 Series A Pulse Module and Meter pints quarts gallons liters 308245N TI1919A Important Safety Instructions Read all warnings an...

Page 2: ... Use the new screws and torque them oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N m See Fig NO TAG 8 Connect the pulse module wires to the cable observing the original wiring polarity Fig 1 1 2 Replacement screws included Torque oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N m 040 89 To Verify the Accuracy of a Pulse Meter Module 1 Use a clean calibrated container If using a single co...

Page 3: ...parately 1 Torque oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N m 040 89 Wire Color Function Red Power Black Ground Electronic Pulse Meter Horizon Model 238618 Series A Measures in pints quarts gallons or liters 1 239367 Electronic Pulse Module Horizon 1 2 Metering Unit cannot be ordered separately 1 1 2 Replacement screws included Torque oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N...

Page 4: ...t Pulse Meter Pressure Loss Flow Rate gpm Crankcase Viscosity Gear Viscosity ISO No 1 2 3 4 5 6 7 8 9 10 11 12 5w 22 4 8 14 19 25 32 37 43 51 58 66 74 10w 32 6 12 20 28 36 46 54 63 74 85 96 108 ATF 7 15 25 35 45 57 67 79 92 106 120 135 Hyd 46 9 17 29 40 52 66 78 91 106 122 138 155 20w 68 13 25 42 59 76 100 115 134 157 181 204 229 30w 100 19 37 62 87 112 144 169 197 231 266 300 337 40w 150 28 56 94...

Page 5: ...308245 5 Notes ...

Page 6: ...y shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warran...