4

308245

Technical Data

Category

Data

Electrical input voltage

15 V maximum

Current loop output

Models 236763, 236764:

4 milliamps OFF
10 milliamps ON

Voltage loop output

Model  238618: 

0 V OFF, 15 V maximum ON

Wiring gauge required

Models 236763, 236764: 

Up to 200 ft (61 m), 18 AWG 2 Wire 90 Volt
201–500 ft (61.3–152.4 m), 16 AWG 2 Wire 90 Volt
501–1000 ft (152.7–305 m), 14 AWG 2 Wire 90 Volt

Model 238618:

 

Up to 50 ft (15.3 m), 18 AWG Shielded 3 Cable

Maximum fluid flow (see Pressure Drop Chart)

12 gpm (45.6 lpm) maximum

Maximum operating pressure

1500 psi (10.3 MPa, 103 bar)

Inlet/Outlet

1/2 npt

Pressure Drop Chart

Pulse Meter Pressure Loss

(Flow Rate – gpm)

Crankcase 

Viscosity

Gear 

Viscosity

ISO No.

1

2

3

4

5

6

7

8

9

10

11

12

5w

–––

22

4

8

14

19

25

32

37

43

51

58

66

74

10w

–––

32

6

12

20

28

36

46

54

63

74

85

96

108

ATF

–––

–––

7

15

25

35

45

57

67

79

92

106

120

135

Hyd.

–––

46

9

17

29

40

52

66

78

91

106

122

138

155

20w

–––

68

13

25

42

59

76

100

115

134

157

181

204

229

30w

–––

100

19

37

62

87

112

144

169

197

231

266

300

337

40w

–––

150

28

56

94

131

169

216

253

295

347

398

450

506

50w

90w

220

41

82

137

192

247

316

371

433

509

584

660

742

–––

–––

320

60

120

200

280

360

460

540

630

740

850

960

1080

–––

140w

460

86

172

287

402

517

661

776

906

1064 1222 1380

The above table indicates the actual pressure drop through the bare meter at 70

_

 F. The shaded area indicates a

flow rate for a given fluid that may not be a good choice for a cost effective system.

Summary of Contents for EFC C Series

Page 1: ...ectronic Fluid Commander Model No 223655 Series C Replacement Pulse Module Model No 236763 Series A Pulse Module and Meter pints quarts gallons Model No 236764 Series A Pulse Module and Meter liters Horizont Model No 239367 Series A Replacement Pulse Module Model No 238618 Series A Pulse Module and Meter pints quarts gallons liters 308245N TI1919A Important Safety Instructions Read all warnings an...

Page 2: ... Use the new screws and torque them oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N m See Fig NO TAG 8 Connect the pulse module wires to the cable observing the original wiring polarity Fig 1 1 2 Replacement screws included Torque oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N m 040 89 To Verify the Accuracy of a Pulse Meter Module 1 Use a clean calibrated container If using a single co...

Page 3: ...parately 1 Torque oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N m 040 89 Wire Color Function Red Power Black Ground Electronic Pulse Meter Horizon Model 238618 Series A Measures in pints quarts gallons or liters 1 239367 Electronic Pulse Module Horizon 1 2 Metering Unit cannot be ordered separately 1 1 2 Replacement screws included Torque oppositely and evenly to 3 to 5 in lb 0 34 to 0 57 N...

Page 4: ...t Pulse Meter Pressure Loss Flow Rate gpm Crankcase Viscosity Gear Viscosity ISO No 1 2 3 4 5 6 7 8 9 10 11 12 5w 22 4 8 14 19 25 32 37 43 51 58 66 74 10w 32 6 12 20 28 36 46 54 63 74 85 96 108 ATF 7 15 25 35 45 57 67 79 92 106 120 135 Hyd 46 9 17 29 40 52 66 78 91 106 122 138 155 20w 68 13 25 42 59 76 100 115 134 157 181 204 229 30w 100 19 37 62 87 112 144 169 197 231 266 300 337 40w 150 28 56 94...

Page 5: ...308245 5 Notes ...

Page 6: ...y shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warran...