Installation

Reservoir

Mount reservoir [Fig. 2, item (P)] on sturdy flat surface
with 6, 3/8 in. diameter bolts. Note location of fill port
(K), hydraulic lines, and lubricant outlet port (G) for
easy access once installed.

Hydraulic system must depressurized before
connecting high pressure hydraulic supply line.

WARNING

CAUTION

Hydraulic supply must be 10

μ

 filtered or better and

supply 0.5 – 3.0 gpm (1.9 – 11.4 lpm) at 800 psi –
3500 psi (55 bar – 241 bar, 5.5 MPa – 24 MPa).

1.

Read instruction manual 308156 (included) before
installing this product.

2.

Install ball valve (Fig. 2, item AA) (user provided)
in the 3/8” hydraulic supply line ( X).

3.

Connect the 3/8” hydraulic supply line (X) to the
swivel (Y).

4.

Connect the 3/4” hydraulic tank line (T) to the
swivel (Z).

5.

Connect the 24 VDC timer controlled signal to 
the 3–way solenoid valve (F).

6.

Connect supply line (G) to the lubricant swivel (C).

7.

Ground system (see 

Grounding

 below). Mount

reservoir to grounded chassis member.

Grounding

 

(for non–mobile installation)

Loosen  grounding lug locknut [Fig. 1 item (A)] and 
washer (B). Insert one end of a 12 ga (1.5 mm

@

)

minimum ground wire (C) into  slot in lug (D) and
tighten  locknut securely. Connect other end of wire to
true earth ground.  To order a ground wire and clamp,
order part number 222011.

0720

Fig. 1

C

A

B

D

Vent Valve Kit for Custom Tank (Part
Number 243170) Installation (See Figure 3)

1.

Weld the bracket (see Fig.5 ) in place per recom-
mended configuration for mounting the vent valve .
Paint the bracket if desired.

2.

Connect the hydraulic control line (Fig. 3, 
item A) to the control module vent valve hydraulic
control line (Fig. 4, item J).

3.

Connect the high pressure lubricant line (Fig. 3, 
item C) feeding the injector system to the lubricant
output (E).

4.

Connect the vent line (F) to the lubricant reservoir.

Control Module Kit for Custom Tank (Part
Number 243501) Installation (See Figure 4)

1.

Mount the control module on a flat, sturdy surface
per the recommended configuration (see Fig.2 )

2.

Connect the hydraulic tank line (Fig. 4, item G)  to
the pump hydraulic outlet port.

3.

Connect the vent valve hydraulic control (J) con-
nection to the hydraulic control line (Fig. 3, item A).

4.

Connect the pump high pressure hydraulic line
(Fig. 4, item H) to the pump hydraulic input port.

5.

Connect the high pressure hydraulic supply to the
high pressure hydraulic supply connection (L) and
the tank lines to the hydraulic tank connection (K).

6.

Connect the 3–way solenoid valve (P) to the timer.

Note:  

Coil should always be installed with lettering

facing out.

Summary of Contents for Dynastar 243159

Page 1: ...system to reset the injectors 5 1 Dynastarr Pump Module Part No 243159 Series C Part No 243502 35 Custom Tank Installation Part No 243503 120 Custom Tank Installation Part No 243504 400 Custom Tank I...

Page 2: ...oute hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 82_C 180_F or below 40_C 40_F D Do not lift pressurized equipment D Comply...

Page 3: ...om starting unexpectedly INJECTION HAZARD Fluid from the dispensing valve leaks or ruptured components can inject fluid into your body and cause extremely serious injury including the need for amputat...

Page 4: ...line parallel automatic lubrica tion system The module requires a hydraulic power Supply and a timed signal from a lubrication controller Based on these signals the pump module provides lubricant flow...

Page 5: ...ly Connect other end of wire to true earth ground To order a ground wire and clamp order part number 222011 0720 Fig 1 C A B D Vent Valve Kit for Custom Tank Part Number 243170 Installation See Figure...

Page 6: ...bricant output connection D Pump module E Ignition switch F 3 Way solenoid valve G High pressure lubricant supply lines H Injector banks J Lubrication controller K Fill port L Overflow port M Breather...

Page 7: ...E F Fig 4 Control Module Installation Kit 243501 KEY G Pump tank line H Pump high pressure hydraulic line J Vent valve hydraulic control K Hydraulic tank connection L High pressure hydraulic connectio...

Page 8: ...8 309098 Installation Fig 5 9653A Vent return port 1 2 npt f Vent valve bracket weld locations Pump mounting 343 or 5 16 18 4X Control module 343 or 5 16 18 2X 18 0 Max 5 0 5 0 6 875 3 536 3 536...

Page 9: ...rvoir 1 Connect lubricant supply hose from remote filling station pump to fill port Fig 2 item K 2 Connect automatic lube system main supply line G to vent valve U outlet 3 Remove plug from overflow p...

Page 10: ...ue to restrictions in tank line or plumbing too small Refer to manual 308156 Increase timer pump on setting Increase hydraulic flow rate to pump Repair or replace Turn pressure up or supply on Replace...

Page 11: ...11 309098 Parts Drawing 1 3c 3d 3e 3f 3g 3h 3a 7 5 8 9652B Pump hydraulic outlet Pump hydraulic inlet Pump lubricant outlet 3i...

Page 12: ...e to 15 20 ft lbs 20 27 Nm lubricate o ring with oil before installation Item 4d Torque to 20 25 ft lbs 27 34 Nm lubricate o ring with oil before installation Item 4e Torque to 15 20 ft lbs 20 27 Nm l...

Page 13: ...2m 194995 HOSE vent 1 2 in 1 2n 238370 HOSE 2 2p 242063 VALVE vent 1 see manual 309099 2q 156684 UNION adapter 1 Ref No Part No Description Qty 3 241486 KIT reservoir 90 grease 1 3a 100737 PLUG pipe...

Page 14: ...swivel Figure 3 item T Hydraulic tank line size 3 4 nps swivel Figure 3 item X Lubricant outlet port size 1 2 nps swivel Figure 3 item G Grease capacity 90 lb Mounting holes for pump module Six 7 16 h...

Page 15: ...15 309098 Hydraulic Control Module Circuit 243501 Does not include pump and pump valve kit...

Page 16: ...remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any a...

Reviews: