Low Level Sensor
When grease is present the LED is green. When the
lubricant level in the reservoir reaches approximately
30% (low level), the LED turns to an amber color. See
FIG. 3 and the table below.
At 30% capacity, the amber low level signals the tank is
reaching a point where the operator should refill the
tank. There is still lubricant in the tank and immediate
shutdown in not required.
If you are using a GLC2200 (part number 24N468,
Series F or later only), the system will enter a low level
warning condition (LL03) after the switch input is closed
for more than 1 second. However, the pump continues
to operate.
F
IG
. 3
Keep the sensor protective cover (12c on page 17)
installed to prevent sensor damage.
Low level sensor wiring instructions begin below.
Graco GLC2200 (part number 24N468, Series F or later
only) can be used to run the pump and monitor the low
level. Refer to FIG. 5 for Low Level Sensor wiring in sys-
tems controlled with a GLC2200. A Low Level Sensor
cable (part number 129072) and a GLC2200 Wiring
Harness (part number 24P314) are required.
Condition
LED Color
Out 2 (Pin #2)
(See Fig. 12, )
Grease present
Green
0VDC
No grease present
Amber
24 VDC