Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in 
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty 
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by 
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Ohio Information

For the latest information about Graco products, visit 

www.graco.com

.

For patent information, see 

www.graco.com/patents

.

TO PLACE AN ORDER, 

contact your Graco distributor or call to identify the nearest distributor.

Toll Free: 

1-800-746-1334

 or Fax: 

330-966-3006

Summary of Contents for Dispensit 1052

Page 1: ...138 bar Maximum Outlet Fluid Working Pressure Metal Sleeves 1200 psi 8 MPa 83 bar Maximum Material Inlet Pressure Plastic Sleeves 400 psi 2 8 MPa 28 bar Maximum Material Inlet Pressure 100 psi 0 7 MP...

Page 2: ...nfigurations 7 Typical Feed System Components 8 Typical Feed System Components continued 9 Metering Valve 10 Setup 11 Typical Installation 11 Valve Mounting Diagram 12 Startup 13 Adjusting the Shot Si...

Page 3: ...s wear impervious gloves when spraying or cleaning equipment If this equipment is used with isocyanate material see additional information on isocyanates in Iso cyanate Conditions Section of this manu...

Page 4: ...ine manu facturer s replacement parts only Do not alter or modify equipment Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic a...

Page 5: ...med solvents which may contain moisture Always keep solvent containers closed when not in use Always lubricate threaded parts with ISO pump oil or grease when reassembling Changing Materials When chan...

Page 6: ...n a grounded surface Do not place the pail on a nonconductive sur face such as paper or cardboard which interrupts grounding continuity Overview This single component meter and dispense device accurat...

Page 7: ...Configurations FIG 1 R GREEN GREEN YELLOW YELLOW 0 TIMER DISPENSE Liquid Control R PRESSURE SYSTEM REG 1 REG 2 AUXILIARY PRESSURE G 1 G 2 OFF ON PB 1 SW 1 PL 1 TR 1 HAND OFF SW 2 POWER AUTO START Val...

Page 8: ...D WEARING SAFETY GLASSES WARNING F 20 0 psi 0 20 oz Cartridge Feed with Mounting Post 5 Gallon Pail Cover with Diaphragm Pump 1 Gallon Ram and Pump 5 Gallon Pail Cover with Diaphragm Pump and Agitator...

Page 9: ...inued FIG 3 R 0 12 8 4 psi 30 22 19 15 26 R 0 12 8 4 psi 30 22 19 15 26 5 Gallon Tank with Diaphragm Pump and Stand 5 Gallon Tank with 5 1 Pump and Stand 10 Gallon Tank with Diaphragm Pump Agitator Va...

Page 10: ...OW Key A Material Inlet C Grounding Lug D Spool E Metering Rod F Oil Cup Retaining Block G Extend Air Inlet H Retract Air Inlet J Dispense Air Inlet K Reload Air Inlet L Extend Air Flow Adjustment Kno...

Page 11: ...s 3 Connect each 1 4 in outside diameter supplied air line to the corresponding control solenoid See Component Identification starting on page 7 4 Connect chemical lines from feed system to meter ing...

Page 12: ...250 188 1 250 1 062 625 8 32 X 38 DP 2 PLACES 126 128 X 25 DP FOR 1 8 DOWEL PINS 2 PLACES 312 C BORE FOR 95 0503 00 O RING 2 PLACES OUT IN 7 88 NEEDLE 50 1 44 3 6 MAX 1 8NPT MAT L INLET 0 0 750 937 0...

Page 13: ...ed pressure 3 Dispense several full stroke shots until material is air free and has good shut off at the nose NOTE Very viscous compressible materials may con tinue to droll after system is primed Red...

Page 14: ...tate the shot size locking ring counterclockwise to loosen 2 Rotate the shot size adjuster to adjust shot size 3 Rotate the shot size locking ring clockwise to tighten 4 Dispense into waste container...

Page 15: ...g chambers by a pressurized feed system Outlet port is blocked Metering rod is retracted to a precise position deter mining the volume of each material Step 2 Shift The balanced spool shifts to the di...

Page 16: ...Shutdown 1 Perform Pressure Relief Procedure 2 Inspect the metering rod for material buildup Clean as necessary 3 Lubricate the metering rod with compatible lubricant such as mesamoll or silicone oil...

Page 17: ...quate input pressure Blocked needle Check needle for cured material replace as required Flow control valve closed Open needle Metering valve not discharging nor mal or full volume Low material level...

Page 18: ...from the air supply Tee Fittings 17 17 Do not remove the fittings themselves 6 Remove the material inlet line from the Inlet Block 34 7 Remove the dispense valve from its mounting FIG 8 1 SCREW CAP 6...

Page 19: ...ning Ring 6 and Washer 7 from the Divorced Section 10 Remove the U cup seal 8 22 Remove the Dispense Sleeve 14 from the Main Body 27 23 Remove the Screws 20 that hold the Seal Plate Cups 26 to each si...

Page 20: ...the left Seal Plate Cup 26 using four Screws 18 Tighten the screws in a cross pattern gradually to prevent binding due to misalignment like you would tighten lug nuts on a car tire 13 Push the Spool i...

Page 21: ...400 psi 2 8 MPa 28 bar Supplied Air Requirements 1 to 3 cfm at 80 psi to 100 psi Shot Size Range depending on metering rods selected 0 002 cc to 3 600 cc Maximum Cycle Rate application dependent heat...

Page 22: ...or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRE...