background image

Installation

311486E  EN

3

Install the Kit

1. Install the solenoid (7), positioning the wires so they 

will not interfere with the clip (C). Secure with the 
clip (C) and screws (D). Torque to 100 in-lb (11.3 
N•m). See F

IG

. 3. Connect the solenoid cable to the 

connector on the underside of the module (1). See 
F

IG

. 1.

2. Install the reed switch sensor (5) and secure with 

the screw (6) and o-ring (13). See F

IG

. 3. Connect 

the sensor cable to the connector on the underside 
of the module (1). See F

IG

. 1.

3. Install the DataTrak

 housing (2) to the air valve 

(G) with two screws (4). See F

IG

. 3.

4. Tuck the sensor wires and solenoid wires under the 

strain relief in the DataTrak

 module (1). Install the 

module to the housing (2) with two screws (3).

5. Reinstall the air valve cover (B) with one screw, 

positioning the wires in the notch of the housing (2). 

6. Install the new cover (8).

7. Reconnect the air line to the motor.

Check for Proper Assembly

1. Enable runaway 

 and set the runaway limit.

2. Run the air motor at a speed slower than the 

runaway limit.

3. Check for proper reed switch operation.

a. The DataTrak pump icon should match the 

movement of the air motor piston.

b. The Grand Totalizer and Batch Totalizer should 

increase by 1 for every air motor cycle.

4. Check for proper runaway operation.

a. After 5 consecutive cycles of the air motor 

running faster than the runaway limit, the 
DataTrak should stop the air motor and display 

the runaway diagnostic screen.

b. Follow the runaway reset instructions in the 

NXT air motor manual 311238.

c. After resetting, turn on the air supply. The air 

motor should run.

d. Shut off the air.

5. Configure the DataTrak as needed. See the NXT air 

motor manual 311238 for all DataTrak operation 
instructions.

Replace Battery or Fuse

See the NXT air motor manual 311238 for complete 
DataTrak instructions.

See the NXT air motor manual 311238 for setup 
mode instructions.

Graco recommends setting runaway to 60.

To reduce the risk of fire and explosion, the 
battery and fuse must be replaced in a 
non-hazardous location. Follow all instruc-
tions in the NXT air motor manual.

Use only an approved replacement battery, 
and an approved fuse (see NXT air motor 
manual). Use of an unapproved battery or 
fuse will void Graco’s warranty and Intertek 
and Ex approvals.

WARNING

WARNING

WARNING

WARNING

Reviews: