9
SHOT FLOW screen
PUMP MODE
SHOT Button
When the SHOT Button is selected, the machine pump will run one cycle when the foot switch or START
CYCLE button is pressed. Depending on shot size, the machine may take more than one shot.
OFF Button
When this button is selected the power to the material pump servomotor will be disabled.
CONT Button
The purpose of this button is to allow the machine continually cycle the pumps in order to empty material
from the tanks when a start device is pressed.
RECIRC button
When this button is selected, the material pump servomotor will cycle at preset rate to make a flow rate
needed for material recirculation.
NOTE:
Prior to using this button, you should turn the required ball
valves to the recirculation position of the corresponding tank.
See the tank recirculation section of this
manual for more information.
PUMP MODE
HOME Button
The pumps will immediately move to the home limit switch and remain in the home position. This position
is used when the machine ready to dispense material.
EXTEND Button
The pumps will immediately move to the retract limit switch and remain in the retracted (parked) position.
RETRACT Button
The pumps will immediately move to the retract limit switch and remain in the retracted (parked) position.
This is used for machine shutdown or when the machine remains inactive or idle for long periods of time.