Repair
3A8564C
19
3. Apply anti-seize to the threads on both ends of the
cylinder (116) and screw the cylinder into the outlet
housing (109). Note the cylinder is symmetrical so
either end can be used. See F
. 25. Torque to the
following specifications:
Throat Seal Installation L100CE and
L200CE
1. Lubricate the O-ring (108), install onto the seal
cartridge (107) and apply anti-seize to the seal
cartridge threads. Install the seal cartridge into the
outlet housing (109). See F
. 26. Torque to the
following specifications:
2. Lubricate the upper shaft seals (106) and inside
diameter of the seal cartridge (107). Install the first
upper shaft seal with the spring side facing the seal
cartridge. Using a suitable size socket or dowel
press the upper shaft seal down into the seal
cartridge until it seats into the bottom of the seal
cartridge.
3. Place the second upper shaft seal (106) into the
seal cartridge (107) with the spring side facing
outwards. Press the shaft seal into the seal
cartridge until it seats against the first upper shaft
seal. See F
. 27.
4. Install the O-Ring packing (104) into the upper
groove of the shaft seal retainer (103).
NOTE:
For L100CE pump, install the packing O-ring
(105) into the groove on the bottom of the retainer.
Displacement Pump
Torque
100 cc
250 Ft-lbs (339 N•m)
200 cc
390 Ft-lbs (529 N•m)
F
IG
. 25
Displacement Pump
Torque
100 cc
250 Ft-lbs (339 N•m)
200 cc
390 Ft-lbs (529 N•m)
116
119
109
F
IG
. 26
F
IG
. 27
107
108
109
106
107