Advanced Programming
332298J
35
Models with Firmware 6.06 and
later for non-DMS models.
Models with Firmware 7.09 and
later for DMS models
A12 - Prelube Sequences
This function changes the behavior of the prelube function to
add more lubrication sequences upon pump start up. While
running multiple sequences, after the initial sequence, PL:xx
will be displayed showing how many sequences are left.
Note: if pump has option “08” and using a pressure switch
with multiple sequences, a vent delay time must be pro
-
grammed under Advanced Programming Option A3.
Prelube LED illuminates (F
. 29)
1. The default 0001 is displayed.
When Prelube is on, it will run one
sequence.
2.
Press the UP or DOWN ARROW
button until desired
number of prelube
sequences displays.
NOTE:
When prelube is on, and the pump is pow
-
ered-up, the pump will run this amount of lubrication ON
sequences.
3. Press the ENTER button to exit Advanced
Programming after the last digit of the pre
-
lube sequence is displayed.
A13- MM:SS OFF Time
This function changes the programming of the OFF Time.
OFF and Warning LEDs Illuminate
1.
The default OFF is dis
-
played. OFF/Backup
time in setup mode is
displayed in HH:MM
(Hours/Minutes).
2.
Press the UP or DOWN ARROW
to change OFF to ON on the dis
-
play. The OFF/Backup Time in
setup mode will be displayed in
MM:SS (Minutes/Seconds).
3. Press the ENTER button to exit Advanced
Programming.
F
IG
. 31
F
IG
. 32