310528
17
Installation
Heater Resistance Checks
WARNING
ELECTROCUTION HAZARD
To reduce risk of injury or damage to
equipment, conduct these electrical
checks with the main disconnect OFF.
To check heater resistance:
1. Make sure the power is off and that the disconnect
switch is in the OFF position.
2. Make electrical resistance checks for the compo-
nents. Refer to
Schematics
on page 67 for wiring
diagram information.
3. Replace any parts whose resistance readings do
not comply with the ranges listed in the chart
below.
NOTE:
Check resistance at ambient room tempera-
ture (63
_
– 77
_
F).
Heaters for 3-Zone Control Panels
Zone Component
Terminals
Value
Range
1
Follower
2L1 & 2L2
98 – 127
h
2L2 & 2L1
ohms
2
Dispense Hose
1532 &
1551
See
Technical
Data
supplied
w/Hose
3
Dispense Gun
1602 &
1621
See
Technical
Data
supplied
w/Gun
Heaters for 4-Zone Control Panels
Zone Component
Terminals
Value
Range
1
Follower
3L1 & 3L3
98 – 127
h
3L2 & 3L3
ohms
2
Dispense Gun
1532 &
1551
See
Technical
Data
supplied
w/Gun
3
Dispense Hose
1602 &
1621
See
Technical
Data
supplied
w/Hose
4
Pump
5L1 & 5L2
187.2 ohms
"
24 ohms
Summary of Contents for 918334
Page 12: ...12 310528 Notes...
Page 36: ...36 310528 Service Fig 10 240 Volt Ram Plate Assembly Wiring 9599A 3L1 3L2 3L3 5L1 5L2...
Page 40: ...40 310528 Notes...
Page 44: ...44 310528 Notes...
Page 52: ...52 310528 Notes...
Page 68: ...68 310528 Schematics 617300 Page 2 9605A...
Page 69: ...310528 69 Schematics 617485_1 9606A...
Page 70: ...70 310528 Schematics 617485_2...
Page 71: ...310528 71 Schematics 617484 Page1 9608A...
Page 72: ...72 310528 Schematics 617484 Page2 9609A...
Page 73: ...310528 73 Schematics 617349 Page1 9689A...
Page 74: ...74 310528 Schematics 617349 Page 2 9690A...
Page 84: ...84 310528 Appendix New Style Temperature Controller Settings List...