16
310528
Installation
Checking Resistance
WARNING
ELECTRIC SHOCK HAZARD
Do not open the electrical control panel,
unless you are a trained professional.
Before opening the control panel, make sure that
all power has been removed from the control panel.
Sensor Resistance Checks
WARNING
ELECTROCUTION HAZARD
To reduce risk of injury or damage to
equipment, conduct these electrical
checks with the main disconnect OFF.
The supply unit includes either three or four heat sen-
sors and controllers for each heated zone. To check
sensor resistance:
1. Make sure the power is off and that the disconnect
switch is in the OFF position.
2. Make electrical resistance checks for the compo-
nents. Refer to
Schematics
on page 67 for wiring
diagram information.
3. Replace any parts whose resistance readings do
not comply with the ranges listed in the chart
below.
NOTE:
Check resistance at ambient room tempera-
ture (63
_
– 77
_
F).
3-Zone RTD Sensors
Zone Component Terminals Value Range
1
Follower
1311 &
1321
107 – 109 ohms
2
Dispense
Hose
1531 &
1541
97.4 –
102.8 ohms
3
Dispense
Gun
1601 &
1611
97.4 –
102.8 ohms
4-Zone RTD Sensors
Zone Component Terminals Value Range
1
Follower
1311 &
1321
107 – 109 ohms
2
Dispense
Hose
1531 &
1541
97.4 –
102.8 ohms
3
Dispense
Gun
1601 &
1611
97.4 –
102.8 ohms
4
Pump
1381 &
1391
97.4 –
102.8 ohms
Summary of Contents for 918334
Page 12: ...12 310528 Notes...
Page 36: ...36 310528 Service Fig 10 240 Volt Ram Plate Assembly Wiring 9599A 3L1 3L2 3L3 5L1 5L2...
Page 40: ...40 310528 Notes...
Page 44: ...44 310528 Notes...
Page 52: ...52 310528 Notes...
Page 68: ...68 310528 Schematics 617300 Page 2 9605A...
Page 69: ...310528 69 Schematics 617485_1 9606A...
Page 70: ...70 310528 Schematics 617485_2...
Page 71: ...310528 71 Schematics 617484 Page1 9608A...
Page 72: ...72 310528 Schematics 617484 Page2 9609A...
Page 73: ...310528 73 Schematics 617349 Page1 9689A...
Page 74: ...74 310528 Schematics 617349 Page 2 9690A...
Page 84: ...84 310528 Appendix New Style Temperature Controller Settings List...