Overview of the Temperature Controller Settings
The basic program settings for each temperature
controller satisfy most application needs. These set-
tings are preset at the factory, but can be changed.
The input type, temperature scale, and over tempera-
ture alarm point are the critical controller settings that
you must check before doing an auto-tune or using
any controller in normal operation. See form# 309100
for operation of the temperature controls.
Graco Factory P, I, and d Settings
Table 1 lists the P, I, and d settings for standard control
panels. These settings are preset at the factory. See
form# 309100 for accessing these values and use the
table for reference information only.
Table 1. Graco Factory P, I, and d Settings
Category
P
I
d
Unit Voltage
Follower
2
326
49
480
Hose
.8
63
9
ALL
Pump
4.2
1081
162
480
Gun
2.1
126
19
ALL
These P, I, and d values are usually generated by
running an autotune process for each heat zone. The
controllers will automatically find the proper P (propor-
tional), I (integral), and d (derivative) values during this
autotune process. These are values that allow the heat
zones to reach their maximum temperature as fast as
possible without significantly exceeding desired tem-
perature.
Summary of Contents for 918334
Page 12: ...12 310528 Notes...
Page 36: ...36 310528 Service Fig 10 240 Volt Ram Plate Assembly Wiring 9599A 3L1 3L2 3L3 5L1 5L2...
Page 40: ...40 310528 Notes...
Page 44: ...44 310528 Notes...
Page 52: ...52 310528 Notes...
Page 68: ...68 310528 Schematics 617300 Page 2 9605A...
Page 69: ...310528 69 Schematics 617485_1 9606A...
Page 70: ...70 310528 Schematics 617485_2...
Page 71: ...310528 71 Schematics 617484 Page1 9608A...
Page 72: ...72 310528 Schematics 617484 Page2 9609A...
Page 73: ...310528 73 Schematics 617349 Page1 9689A...
Page 74: ...74 310528 Schematics 617349 Page 2 9690A...
Page 84: ...84 310528 Appendix New Style Temperature Controller Settings List...