Definitions
20
313903B
Definitions
Data
Definition
R1z
Read settings of Zone 1 or 2. The z is set to either 1 or 2. The returned message is a data
structure arranged in the following order:
a.
BYTE
- 0 or 1 indicates whether the zone is enabled
b.
BYTE
- Unit of measurement on the display
0 = Ounces
1 = Pints
2 = Gallons
3 = Liters
4 = Millimeters
5 = Counts
c.
BYTE
- Interlock of alarms
0 = Alarm Disabled
1 = Alarm Zones Interlocked (First Alarm)
2 = Alarms Independent
d.
BYTE
- Alarm Generation
0 = Low Flow Alarm Only
1 = High Flow Alarm Only
2 = Both Low and High Flow Alarms
e.
BYTE
- 0 or 1 indicates whether the Tachometer is enabled.
f.
INTEGER
- Block Total
g.
INTEGER
- Low Flow Limit for Alarm
h.
INTEGER
- High Flow Limit for Alarm
i.
INTEGER
- Tachometer Setting for Normal RPM
j.
BYTE
- Tach Pulses per RPM
R2z
Read the current status of Zone 1 or 2. The z is set to either 1 or 2. The returned message
is a data structure arranged in the following order:
a.
BYTE
- Cycle Position. Indicates if the input is opened or closed (0 or 1).
b.
INTEGER
- Cycle Timer. Running time in 0.1 seconds since start of cycle.
c.
INTEGER
- Last Cycle Time. Time of the last cycle.
d.
INTEGER
- Cycle Count. Number of cycles since last reset.
e.
BYTE
- Fault Status (N/F) for Normal or Fault.
R3
INTEGER
- Read Current RPM.
R4
BYTE
- Read the number of faults skipped before signaling a fault (value = 1, 2 or 3).
R5
BYTE
- Read if relay output is inverted.
0 = Normal
1 = Inverted