background image

307133

5

Installation

Fig 2

9

Refer to Fig 3

A

B

C

D

E

FLUID

AIR

7857

Fig 3

9d

Air To Tank

9d

Air From Compressor

9e

Air To Gun If Single 
Regulated Tank, 
Or
Air To Atomizing 
Regulator If Dual 
Regulated Tank

11

Air Atomizing
Regulator If Dual
Regulated Tank

10

Air to Gun If Dual
Regulated Tank

9a

9b

9c

12

For Dual 
Regulated
Tank Only

For Single and Dual 
Regulated Tanks

7858 rev

16

Inlet 
Port
All
other
ports
outlet

About the single-regulated tank (Model 171226)
When the air pressure to the tank and the spray gun at-
omizing air are controlled by one regulator, the same
pressure is delivered to both.

About the dual-regulated tank (Model 223883)
For separate control of the atomizing air, a separate at-
omizing air regulator for the tank is supplied. See To add
an air atomizing regulator
, below.

NOTE: Use thread sealant on all male threads.

All tanks
Install an air filter upstream from the regulator to remove
dirt and moisture from your air supply.

Screw the riser tube (E) into the pipe fitting on the bottom
side of the tank cover. See Fig 1.

Single-regulated tank
Assemble the air regulator (9) as shown in Fig 2. Screw
the regulator assembly into the port marked AIR on the
tank cover.

Screw the handle (A) and the nut (C) onto the cover, and
tighten them securely. See Fig 1.

Connect an air supply hose to the 1/4 npt air inlet nipple
(9d). Connect the gun’s air atomizing hose tee fitting (9e).
Connect the gun’s fluid hose to the adapter (D), at the
point marked PAINT. See Fig 1.

To add an air atomizing regulator
Remove the handle (A) and nut (C). Remove the tank
regulator assembly (9) and assemble the second regu-
lator to it as shown in Fig 2.

Screw the dual regulator assembly into the tank cover
port marked AIR. Reinstall the handle (A) and nut (C).

Connect the air supply hose to the nipple (9d). Connect
gun’s  air atomizing hose to the nipple (10). Connect the
gun’s fluid hose to the adapter (D), at the point marked
PAINT. See Fig 1.

Install the gun
Connect the air atomizing and fluid hoses to the gun. See
Fig 1.

Grounding
Ground the sprayer as instructed on page 3 before oper-
ating it.

Summary of Contents for 307133P

Page 1: ...sign 50 psi 350 kPa 3 5 bar Maximum Working Pressure Part No 171226 Series C shown Basic portable pressure tank Part No 223833 with Dual Regulators 307133P EN Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ...

Page 2: ... not exceed the maximum working pressure of the lowest rated system component Refer to the Technical Data on page 9 for the maximum working pressure of this equipment D Use fluids and solvents which are compatible with the equipment wetted parts Refer to the Tech nical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings D Do not exceed the maximum working press...

Page 3: ...r you feel an electric shock while using this equipment stop spray ing immediately Do not use the equipment until you identify and correct the problem D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed D Keep the spray area free of debris including solvent rags and gasoline D Electrically disconnect all equipment in the spray area D Ext...

Page 4: ...der Part No 237569 Ground Wire and Clamp 2 Air compressor according to the manufacturer s recommendations 3 Object being sprayed according to local code 4 All solvent pails used when flushing according to local code Use only metal pails which are con ductive Do not place the pail on a non conductive surface such as paper or cardboard which inter rupts the grounding continuity 5 To maintain groundi...

Page 5: ...om your air supply Screw the riser tube E into the pipe fitting on the bottom side of the tank cover See Fig 1 Single regulated tank Assemble the air regulator 9 as shown in Fig 2 Screw the regulator assembly into the port marked AIR on the tank cover Screw the handle A and the nut C onto the cover and tighten them securely See Fig 1 Connect an air supply hose to the 1 4 npt air inlet nipple 9d Co...

Page 6: ...the Pressure Relief Procedure on page 6 CAUTION The pressure tank and cover are coated for corro sion resistance Be sure the paint and solvent you use are compatible with the pressure tank coating and wetted parts Prepare the paint or other coating Follow the manufacturer s recommendations Strain the paint to remove particles or sediment that could clog the spray gun and hose To fill the tank Foll...

Page 7: ... turns Hold a rag over the air cap and trigger the gun to force the paint back through the hose and into the tank Empty the tank Pour a compatible solvent into the tank CAUTION Be sure the solvent you use is compatible with the fluid being sprayed and the hose material Replace the cover and tighten the wing nuts evenly and securely Remove the spray gun air cap Turn on the air supply Trigger the sp...

Page 8: ...ckage of 5 112078 Package of 25 1b 103996 VALVE safety relief 50 psi 3 5 bar 1 1c 244953 GASKET cover polyethylene pkg of 3 1 Ref No Part No Description Qty 9 214979 REGULATOR ASSEMBLY Includes items 9a 9e 1 9a 100139 PLUG 1 8 npt 1 9b 104655 GAUGE air pressure 0 60 psi 0 42 bar 1 9c 104815 AIR REGULATOR See manual 307167 for parts 1 9d 151519 NIPPLE hex reducing 1 8 npt x 1 4 npt 1 9e 181107 TEE ...

Page 9: ...ure 50 psi 350 kPa 3 5 bar Relief valve setting 50 psi 350 kPa 3 5 bar Air inlet size 1 4 npt m Fluid outlet size 3 8 npsm m Air outlet size 1 4 npt m Height 21 in 533 mm Width 11 25 in 286 mm Weight 11 lb 5 kg Wetted parts Coated Aluminum brass steel coated steel buna n polyethylene ...

Page 10: ...ncidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories equipm...

Reviews: