background image

11

309000

System Setup

Fluid and Air Connections

1/4 npt(f) Fluid Inlets

There are three fluid inlets on the A-side and three
fluid inlets on the B-side.  The fluid inlets are located
on the front, side, and back of the valve to permit
various mounting and hose configurations.

1/8 npt(f) Air Inlets

The machine mount valves and the electric switch
hand-held valves have an “open” port and “close” port,
which are operated by a remote 4-way air control
valve.

The air switch hand-held valves have a single air inlet.
This valve also has an internal 4-way spool which
operates the air piston.

See Accessories, page 27, to order air control valves
and tubing.

Inlet Check Valves

Inlet check valves are recommended on the fluid inlets
where viscosity allows.  An inlet check valve prevents
back-flow or crossover when the mixer is plugged or
one fluid is much lighter in viscosity than the other.
When required, a high crack pressure check valve is
installed to maintain back-pressure on low viscosity
fluids.

See Accessories, page 27, for a list of check valves.

Balancing the System

A proportioner is used to feed the two-component
dispense valve.  The system must be pressure bal-
anced to avoid “lead-lag” ratio errors when starting and
stopping the flow.

Balancing is done by hose sizing, inlet check restric-
tion, and nose piece restrictors.  A properly balanced
system has near equal back-pressure on the gauges
when flowing without a mixer installed.

The 2K-UL valve is supplied with 1/8 I.D. and 3/64 I.D.
restrictors (32 and 33) which can be installed in the
nose piece to help balance the system. A special nose
piece outlet that accepts a wide variety of restrictors
with filter screens is available. See application kits
manual 311230.

See Accessories, page 27, for a list of restrictive
catalyst injectors.

Selecting Hoses

Hoses between your proportioner and the 2K-UL valve
should be selected carefully.  Many factors effect hose
selection.

1.

Fluid Compatibility:  Fluid must not degrade the
core material or end fittings of the hose.  Nylon or
PTFE cores are commonly used for chemical
compatibility.  If your fluid is moisture sensitive you
should use PTFE or Moisture-Lok hoses.

2.

Pressure Rating:  Be sure hoses have a working
pressure rating above the pressure capability of
the system.

3.

Compressibility:  Hoses, especially nylon paint
hoses, expand with an increase in pressure.  A
pressure change in the system may cause a
volume change, which can appear as a ratio error
with wide mix ratios.  Compressible hoses absorb
pressure spikes which is helpful to the operator
during an application, such as trying to lay a bead.

4.

Internal Diameter:  Small I.D.’s create higher
back pressures, lower flows, and small retained
volume.  Typically hose I.D.’s are selected for:

a.

System Pressure Balance.  ”A” pressure drop
vs. “B” pressure drop.

b.

Volume Balance.  A:B volume ratio vs. Hose
retained volume.

c.

Flexibility and weight for operator or robot.

d.

Overall Pressure Drop.  Pressure drop should
be minimum possible within the above guide-
lines.

5.

Length:  Hoses normally are kept as short as
practical to minimize pressure drop and compress-
ible volume.  10 ft (3.1 m) is recommended for
reciprocating pump systems.

System Start-up

When initially loading the fluids through the system,
leave the mixer off until both fluids flow freely from the
nose piece without any air.  This prevents cross con-
tamination from having fluid on one side pushing back
up the other side.

Summary of Contents for 2K Ultra-Lite 249591

Page 1: ...ssure 120 psi 0 84 MPa 8 4 bar Maximum Air Inlet Pressure Machine Mount Valves Part No 570145 Aluminum Wide Ratio Part No 570151 For P Dose 1 2 G mixers Part No 965533 Aluminum Wetted Part No 965534 S...

Page 2: ...Checking 14 Maintenance 15 Daily Shut down 15 Preventative Maintenance 15 Troubleshooting 16 Service 17 Disassembly 17 Reassembly 18 Parts 22 Model 570145 570151 570182 965533 965535 965537 249591 23...

Page 3: ...rs to ensure that the fluids being used are compatible with aluminum and zinc parts WARNING PLURAL COMPONENT MATERIALS HAZARD Graco Inc does not manufacture or supply any of the reactive chemical comp...

Page 4: ...MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury D This equipment is for professional use only D Read all instruction manuals tags and lab...

Page 5: ...p the dispense area free of debris including solvent rags and gasoline D Extinguish all open flames or pilot lights in the dispense area D Do not smoke in the dispense area D Do not turn on or off any...

Page 6: ...npt f air to open I 1 4 in npt f A fluid inlet 3 places J 1 4 in npt f B fluid inlet 3 places L Zirk grease fitting M Flush grease fitting N 4 way trigger valve or electric switch O Trigger lock P 1...

Page 7: ...A pilot port can be used to control a pump motor Hand held valve with electric switch The switch signals the customer s controller to open and close the ports on the 2K UL valve using a remote 4 way...

Page 8: ...INALS IN CABLE CONNECTOR AS SHOWN NORMALLY OPEN MOMENTARY CONTACT SWITCH DOT INDICATES GROUND CONNECTION NOTE THIS VALVE IS ACTIVATED BY A REMOTE SOLENOID THE TRIGGER ONLY ACTIVATES THE ELECTRICAL SWI...

Page 9: ...CTRIC SWITCH ACCESSORY FLOW CONTROL FITTINGS TO ADJUST OPEN AND CLOSE SPEED SHAFTS ARE FREE TO ALIGN CHOICE OF ALUMINUM OR STAINLESS WETTED HOUSINGS SNUFF BACK INSERTS ARE REMOVABLE FOR LOW FLOW OR WI...

Page 10: ...sistance of your fluid hoses at least once a week If your hose does not have a tag on it which specifies the maximum electrical resistance contact the hose supplier or manufacturer for the maximum ele...

Page 11: ...hat accepts a wide variety of restrictors with filter screens is available See application kits manual 311230 See Accessories page 27 for a list of restrictive catalyst injectors Selecting Hoses Hoses...

Page 12: ...wo rings are trapped between the main valve body and the nose piece When the fluid valve pulls back to close it enters the restrictions stops flow and pulls the fluid back until the needle reaches its...

Page 13: ...pect that the dispense needle or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the hose end coupling and relieve pressure g...

Page 14: ...uids separately out of the nosepiece into tared cups The cups can then be weighed and the weights divided to get the mix ratio by weight A divided outlet accessory Part no 626611 is avail able to make...

Page 15: ...cross over in the nosepiece 3 Partially fill a plastic disposable night cap Part No 551327 with a moisture free oil 217374 pint or grease 106565 14 6 oz cartridge 4 Push the plastic cap over the valve...

Page 16: ...air pressure Air not exhausted from behind air cylin der piston Use four way relieving type air valve operator Blockage between needle and seat Remove and clean needle and seat Bad or missing gasket b...

Page 17: ...cap o ring 9 Remove the internal C clip 12 Push the two shafts 3 to dislodge the piston 10 assembly from the air cylinder 1 10 Remove the adjustment nuts 8 the pin 7 o rings 9 and piston o ring 6 from...

Page 18: ...the side of the bearings line up with the grease ports in the housing 19 3 Holding the bearings 21 in place push the bear ing assembly over the shafts 3 4 Lubricate the main fluid seals 22 and its cav...

Page 19: ...g 60 into the housing Tighten it to 60 70 in lbs 6 8 7 9 NSm 8 Orient the gasket 30 to the holes on the air cylinder 1 Screw the air valve assembly to the cylinder with the screws 60 and lock washers...

Page 20: ...imer N 7649 and Loctite TL242 243 or equiva lent blue Loctite when installing the needle 27 Tighten to 15 20 in lb 1 7 2 2 NSm Use an anti seize lubricant Loctite 56765 when installing the fluid housi...

Page 21: ...1 3 4 2 5 6 Electric Switch Version 965537 or 965538 64 The electric switch and cable assembly are not ser viceable and can only be replaced as an assembly Application Note This valve is activated by...

Page 22: ...unt Valves 5 7 6 19 1 9 24 36 15 18 25 4 12 30 27 3 8 20 21 22 14 13 23n 33 32 35 40 34 Fig 6 Outlet Details 31 31 37 37 39 38 Model 570151 Models 570145 and 570182 9291A 9290A All 965XXX models 41 41...

Page 23: ...only 1 626631 MANIFOLD NOSEPIECE aluminum Used on 570151 only 1 626061 MANIFOLD NOSEPIECE aluminum Used on 965533 965535 and 965537 only 1 Ref No Part No Description Qty 32 L 626058 RESTRICTOR 1 8 ID...

Page 24: ...n 103926 SCREW 1 4 20 x 2 25 2 24 101970 PLUG 1 4 npt sst 4 25 185467 SEAT C2 carbide 2 26 626052 HOUSING fluid stainless steel 1 27 626062 NEEDLE hardened stain less steel 1 28Y 188377 LABEL skin inj...

Page 25: ...965535 965536 or 249591 58 59 57 56 65 66 67 Electric Switch Version 965537 or 965538 64 Note The electric switch housing switch cable and discon nect are sold and serviced as a complete assembly Air...

Page 26: ...NDLE 1 59 626083 TRIGGER 1 60 106551 O RING 0 5 x 0 6 fluoroelastomer 1 61 178654 GUIDE stem 1 62 626053 PIN trigger 1 63 626056 HOUSING air valve 1 65 104468 SCREW 4 40 x 375 Used on 249591 only 4 66...

Page 27: ...jector No Size Code Bore Dia Needle Dia Typical Application Viscosity Typically Used Sealant 948291 125 125 in 086 in 5000 50 000 cps Polysulfide 948258 35 110 in 086 in 1000 10 000 cps Silicone 94793...

Page 28: ...512294 512014 5 8 O D Fits 1 2 O D 512008 512017 Fits 5 8 O D Mixer 512297 512288 512298 512289 Replacement Nose Piece Restrictors for valves with 1 1 nose piece Size Part Number 1 8 I D 3 64 I D 6260...

Page 29: ...isposable mixer 24 in in front of valve See manual 311230 249765 Restrictor Kit for use with Cold Spray Kit 249634 and Joint Fill Kit 249635 See manual 311230 Conversion Kits Part No Description 94963...

Page 30: ...o rings Weight Aluminum Valve 1 43 lb 0 65 kg Stainless Steel Valve 2 07 lb 0 94 kg Handle Kit 0 77 lb 0 35 kg Wetted Parts Aluminum Valve aluminum 303 stainless steel 17 4 PH stainless steel C2 carb...

Page 31: ...31 309000 Dimensions...

Page 32: ...for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the d...

Reviews: