Operation
16
3A8502A
Daily Startup
1. Verify that the air regulator is set to zero.
2. Open the bleed-type master air valve (AD).
3. Turn on the main air supply.
4. Slowly tighten the air regulator until the transfer
pump runs slowly.
5. Use the air regulator to control the pump pressure.
Daily Shutdown
1. Turn off air supply to the pump.
2. Close the bleed-type master air valve (AD).
3. When air pressure is bled off, set the air regulator to
zero.
NOTICE
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a
high speed and could cause damage to the pump.
If the pump accelerates quickly or starts running too
fast, stop it immediately and check the fluid supply.
If the supply container is empty or air has been
pumped into the lines, refill the container and prime
the pump and the lines with fluid, or flush and leave
it filled with a compatible solvent. Be sure to
eliminate all air from the fluid system.
Do not attempt to operate unless it is securely
mounted in a drum.
WLD
$'
AD