Operation
14
3A8502A
Operation
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid
contaminating your fluid with oil, flush the equipment
with a compatible solvent before using the equipment.
See your system operation manual for instructions to
flush the system equipment.
Pressure Relief Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
1. Shut off the air to the pump.
2. Close the bleed-type master air valve (AD).
3. Open the fluid drain valve (AE).
NOTE:
Follow the pressure relief procedure in your
proportioner manual to relieve pressure downstream
from the transfer pump.
To avoid fire and explosion, always ground equipment
and waste container. To avoid static sparking and
injury from splashing, always flush at the lowest
possible pressure.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
WLD
$'
$(
Summary of Contents for 26D001
Page 31: ...Notes 3A8502A 31 Notes...