Maintenance
14
3A7519A
4.
Reinstall the outlet housing adapter by lining up the
hole in the adapter with the pin on the outlet housing
(F
5.
Using a 2 in. socket, reinstall the throat seal retainer
nut (19) and tighten (torque 150 - 165 ft-lb/203.4 -
223.7 N•m) (F
. 21).
6.
Reinstall the air motor (1) by sliding the
displacement rod (14) through the outlet housing (3)
(F
. 22).
NOTE: Reinstall the air motor in the preferred
orientation for air line connection.
7.
Replace and hand-tighten the outlet housing
adapter bolts (17) (F
F
IG
. 19
F
IG
. 20
F
IG
. 21
F
IG
. 22
F
IG
. 23
1
3
17