Maintenance
10
3A7519A
Maintenance
Suggested tools
1/8 in. hex key
3/4 in. socket
15/16 in. socket
15/16 in. open-end wrench
1-7/16 in. socket
1-13/16 in. socket
1-15/16 in. socket
2 in. socket
socket extension
O-ring pick
Torque wrench (50 - 250 ft-lb/ 67.8 - 339 N•m)
Torque wrench (70 in-lb/ 7.9 N•m)
Large adjustable wrenches (1-1/4 in. jaw capacity)
Disassemble
1.
Close the bleed type master air valve (E, F
stall the pump while it is in the down stroke position
(F
. 3).
2.
Relieve pressure following the
, page 8.
3.
Disconnect the air supply hose from the pump air
motor (1).
4.
Disconnect the fluid hose.
5.
Remove the pump from the container and place on
a workbench.
6.
Remove the muffler (27).
NOTE: Removing the muffler (27) allows easier
movement of the internal pump components to expose
the flats.
7.
Remove the four screws (31) holding the mounting
flange (7) using 1/8 in. hex key (F
. 5).
8.
Remove the mounting flange (7), exposing the flats
(F
. 5).
F
IG
. 3
F
IG
. 4
F
IG
. 5
27
7
31
Flat