Setup
10
3A5202G
Electrical Components
NOTE:
Certain 120 V GFCI outlets have been known to
trip while using this product. GFCI outlets have a range
of sensitivities. Motor controllers can cause false trips of
GFCI outlets. If you experience issues while using this
product, switch to a different GFCI model.
1. Only use a grounded power cord. Plug the cord into
the wall outlet.
2. Verify that the On/Off switch (EA) is in the OFF
position. Plug the power cord (PC) to the electrical
box (E).
Grounding
The system is grounded through the power cord (PC).
Power Supply Requirements
Model
Voltage
Circuit Protection
25M530
110-120 V
15 A Circuit Breaker
25M563
220-230 V
16 A Circuit Breaker
Minimal Power Cord Wire Gauge
Length (ft)
Wire Gauge (AWG)
25
16
50
12
100
10
WLD
PC
E
E
EA
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.