Pump
34
3A5082G
A10 - Low Level Reset Upon Power On.
(Models with Firmware 5.04 and later. DMS
Models with Firmware 7.07 and later.)
This function changes the behavior of the low level upon
pump power on. When A10 is on, a low level fault clears
when the pump power is cycled. The pump will revolve 5
revolutions, checking to see if the low level condition is
still present. If not, it will self clear and continue. If a low
level condition exists during the 5 revolutions, it will go
into a low level fault.
Low Level ON LED illuminates (F
. 28).
1.
The default OFF is displayed. The
alarm output will toggle once a
second.
2.
Press the UP or DOWN
ARROW button to move
through Advanced Options
until Advanced Option A6 is
displayed.
3.
Press the ENTER button.
Time Control
After setup is complete, the pump automatically begins
to run the OFF Time sequence (F
. 29).
•
The pump runs the programmed OFF sequence.
(Notice the OFF Time LED on the display lights and
the OFF Time counts down on the display.)
•
The example shown in F
. 29 shows an OFF Time
of 1 hour and 32 minutes before the lubrication cycle
begins.
•
When the OFF Time count reaches zero, the pump
turns the pump on and it runs for the programmed
ON Time cycle (F
(Notice the ON Time LED is now illuminated on the
display.)
•
The example shown in F
. 30 shows an ON Time of
6 minutes before the lubrication cycle ends.
F
IG
. 28